 ===== when to run opportunity loads ===== ===== when to run opportunity loads =====
  
-The optimal time to run loads is when there is **power in excess of battery charging requirements**.  +The optimal time to run loads is when there is **power available in excess of battery charging requirements**.  
  
-With **lead** this means **during Float**, or **in late Absorption** where charge current acceptance has fallen enough that the system can run the loads //and still maintain the Absorption voltage setpoint//.  +With **lead** this means **during Float**, or **in late Absorption** when charge current acceptance has fallen enough that the system can run the loads //and still maintain the Absorption voltage setpoint//.  
  
-There is a little more wiggle room with [[electrical:12v:deep_cycle_battery#lithium_chemistries|LiFePO4]];  the loads can be run with no net effect on a Lithium system when+There is a little more wiggle room with [[electrical:12v:deep_cycle_battery#lithium_chemistries|LiFePO4]];  the loads can be run with no net negative effect on a Lithium system when
  
   * the bank has reached the intended charge state   * the bank has reached the intended charge state