This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:solar:pwm_tweaking [2017/11/27 17:15] frater_secessus [Tweaking a PWM controller for maximum power] |
electrical:solar:pwm_tweaking [2018/03/24 07:54] frater_secessus [delay loads until after Bulk] |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== Tweaking a PWM controller for maximum power ====== | ====== Tweaking a PWM controller for maximum power ====== | ||
- | [[electrical: | + | [[electrical: |
Note: much of this information also applies to [[electrical: | Note: much of this information also applies to [[electrical: | ||
Line 11: | Line 11: | ||
During charging with a PWM controller **the solar panel will be running at the voltage of the battery bank**. | During charging with a PWM controller **the solar panel will be running at the voltage of the battery bank**. | ||
- | This affects charging in all three [[electrical: | + | This affects charging in all three [[electrical: |
{{ http:// | {{ http:// | ||
- | 17.8v x 5.6A = 99.68w < | + | 17.8v x 5.6A = 99.68w < |
+ | 17.8v x 5.6A = 94.70w <-- MPPT running at 95% efficiency | ||
14.8v x 5.6A = 82.88w <-- power at a high Absorption voltage, as with flooded lead acid \\ | 14.8v x 5.6A = 82.88w <-- power at a high Absorption voltage, as with flooded lead acid \\ | ||
- | 14.4v x 5.6A = 80.64w <-- power at a lower Absorption voltage, as with AGM \\ | + | 14.4v x 5.6A = 80.64w <-- power at a lower Absorption voltage |
+ | 14.2v x 5.6A = 79.52w <-- power at a low Absorption voltage | ||
13.8v x 5.6A = 77.28W <-- power at high Float, as with deeply cycled banks \\ | 13.8v x 5.6A = 77.28W <-- power at high Float, as with deeply cycled banks \\ | ||
13.2v x 5.6A = 73.92W <-- power at low Float, as with lightly cycled banks \\ | 13.2v x 5.6A = 73.92W <-- power at low Float, as with lightly cycled banks \\ | ||
Line 40: | Line 42: | ||
During the bulk charging stage the battery needs every bit of power it can get. Any loads applied during this stage slow down charging and, more importantly, | During the bulk charging stage the battery needs every bit of power it can get. Any loads applied during this stage slow down charging and, more importantly, | ||
- | Wait until your bank is well into Absoroption | + | Wait until your bank is well into Absorption |
==== set Vabs and Vfloat relatively high ==== | ==== set Vabs and Vfloat relatively high ==== | ||