This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Last revision Both sides next revision | ||
electrical:solar:tracer [2022/02/04 14:58] frater_secessus [lithium compatibility] |
electrical:solar:tracer [2022/03/02 13:48] frater_secessus [MT-50 display] bau rate |
||
---|---|---|---|
Line 22: | Line 22: | ||
===== quirks ===== | ===== quirks ===== | ||
- | Some [[electrical: | + | Some [[electrical: |
- | - "Low Voltage Reconnect Voltage" | + | |
- | - "Boost Reconnect" | + | - "Low Voltage Reconnect Voltage" |
+ | - "Boost Reconnect" | ||
- Then "Float Charge" | - Then "Float Charge" | ||
- Then "Boost Charge" | - Then "Boost Charge" | ||
- Then " | - Then " | ||
- | - Then "Over Voltage Reconnect" | + | - Then "Over Voltage Reconnect" |
- | - Then " | + | - Then " |
- | - Then "Over Voltage Disconnect" | + | - Then "Over Voltage Disconnect" |
**PARA errors** mean the internal logic of the setpoints has been violated: | **PARA errors** mean the internal logic of the setpoints has been violated: | ||
Line 36: | Line 37: | ||
> The **following rules** must be observed when modifying the parameter' | > The **following rules** must be observed when modifying the parameter' | ||
- | > Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging Voltage. | + | > Over Voltage Disconnect Voltage |
- | > Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage | + | > Over Voltage Disconnect Voltage |
- | > Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit Voltage. | + | > Low Voltage Reconnect Voltage |
- | > Under Voltage Warning Reconnect Voltage> | + | > Under Voltage Warning Reconnect Voltage |
- | > Boost Reconnect Charging voltage >Low Voltage Reconnect Voltage. | + | > Boost Reconnect Charging voltage > Low Voltage Reconnect Voltage. |
Line 153: | Line 154: | ||
Because of a tweak Renogy made to their version of the controllers, | Because of a tweak Renogy made to their version of the controllers, | ||
+ | |||
+ | Note: some comms problems can be solved by [[https:// | ||
==== MT-75 display ==== | ==== MT-75 display ==== |