User Tools

Site Tools


opinion:frater_secessus:self-heated_lifepo4

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
opinion:frater_secessus:self-heated_lifepo4 [2023/09/03 16:21]
frater_secessus [perfect storm for self-heated batteries]
opinion:frater_secessus:self-heated_lifepo4 [2023/09/03 16:22]
frater_secessus [robust charging]
Line 43: Line 43:
 When you want a packaged solution. When you want a packaged solution.
  
-If you run your bank very low habitually((stop doing that!)) and the warming load is enough to trigger BMS discharge shutdown.  +If you run your bank very low habitually((stop doing that!)) and the warming load is enough to trigger BMS discharge shutdown.  This problem does not occur with self-heated because heating only runs when charging is present. 
  
  
Line 53: Line 53:
 With robust charging (alternator and/or bigger solar) there can be charging opportunities lost with self-heated batteries in freezing conditions.   With robust charging (alternator and/or bigger solar) there can be charging opportunities lost with self-heated batteries in freezing conditions.  
  
-Imagine +Imagine the following scenario
  
-* freezing overnights followed by a half-hour drive in the morning with a 30A DC-DC.  +  * freezing overnights followed by a half-hour drive in the morning with a 30A DC-DC.  
-* a battery with warming pad that consumed 60Wh overnight to stay above freezing, vs +  * a battery with warming pad that consumed 60Wh overnight to stay above freezing, vs 
-* a self-heating battery that is below freezing in the morning+  * a self-heating battery that is below freezing in the morning
  
 The externally warmed bank accepts current immediately and takes **15Ah of recharge**.  So after recouping the 60Wh used overnight it's **net +132Wh**. The externally warmed bank accepts current immediately and takes **15Ah of recharge**.  So after recouping the 60Wh used overnight it's **net +132Wh**.
opinion/frater_secessus/self-heated_lifepo4.txt · Last modified: 2023/10/17 15:13 by frater_secessus