opinion:frater_secessus:solar_harvest [2020/09/24 14:12] frater_secessus created |
opinion:frater_secessus:solar_harvest [2023/02/17 15:07] frater_secessus [ununsual scenarios] |
===== observations ===== | ===== observations ===== |
| |
Overpaneled configurations (relatively high panel watt to batter Ah ratio) tend have two main features: | Overpaneled configurations (relatively high panel watt to battery Ah ratio) tend have two main features: |
| |
- improved charging in adverse conditions | - improved charging in adverse conditions |
- //apparent// low output in normal conditions - this occurs because the batteries are typically in Absorption with battery charging demand dropping by solar noon; there is rarely an opportunity to [[opinion:frater_secessus:http://bdp.mousetrap.net/index.php/2020/07/17/mythtesting-higher-voltage-for-additional-yield-in-the-mornings/|demonstrate full output]]. | - //apparent// low output in normal conditions - this occurs because the batteries are typically in Absorption with battery charging demand dropping by solar noon; there is rarely an opportunity to [[http://bdp.mousetrap.net/index.php/2020/07/17/mythtesting-higher-voltage-for-additional-yield-in-the-mornings/|demonstrate full output]]. |
| |
Note that overpaneled systems are typically only making | |
| |
* full sun normal | * full sun normal |
* 305w, 54% of rated, 4 | * 305w, 54% of rated |
* bright sun through thin / cirrus clouds, shadows thrown | * bright sun through thin / cirrus clouds, shadows thrown |
* 312w at 11am, sea level. 55% of rated, 67% of theoretical. | * 312w at 11am, sea level. 55% of rated, 67% of theoretical. |
| |
* exceptionally high yield, 90% of rated | * exceptionally high yield, 90% of rated |
* [[http://img.mousetrap.net/2020/Screenshot_20200222-114332.jpg|519w at in February in Quartzsite @ noon]], ~500' elevation. 91% of rated, 114% of theoretical. I've seen 500w+ rarely, maybe 3x in two years off grid so far. | * [[http://img.mousetrap.net/2020/Screenshot_20200222-114332.jpg|519w at in February in Quartzsite @ noon]], ~500' elevation. 91% of rated, 114% of theoretical. I've seen 500w+ out of 570w rarely, maybe 3x in two years off grid so far.((before I increased array to 750w)) |
| * wildfire smoke - [[http://img.mousetrap.net/2020/Screenshot_20200908-122938.jpg|8.98W at noon]], sea level. 1.5% of rated, 1.9% of theoretical during September 2020 wildfires in Oregon. |
| |
* wildfire smoke - [[http://img.mousetrap.net/2020/Screenshot_20200908-122938.jpg|8.98W at noon]], sea level. 1.5% of rated, 1.9% of theoretical during September 2020 wildfires in Oregon. | |
| |