 +DRAFT
 +
 ====== sizing a house battery bank ====== ====== sizing a house battery bank ======
  
Line 6: Line 8:
  
  
-Everything in this article assumes you have already assessed your [[electrical:12v:dailypowerrequirements|daily power requirements]] (DPR).  The article will stipulate a DPR of 1,000Wh (1kWh). This 1,000Wh will be the base of all our calculations below.   +  * Everything in this article assumes you have already assessed your [[electrical:12v:dailypowerrequirements|daily power requirements]] (DPR).  The article will stipulate a DPR of 1,000Wh (1kWh). This 1,000Wh will be the base of all our calculations below.   
- +  * We will think in terms of 12v systems and 100Ah batteries.   
-We will assume lithium = the common LiFePO4 and not any other form of lithium chemistry.+  We will assume lithium = the common LiFePO4 (12.8v)
  
  
Line 19: Line 21:
 === usable capacity === === usable capacity ===
  
-  * lead-chemistry batteries (FLA, AGM, GEL) are typically [[electrical:nominal|nominal]] 12v and discharged to 50% [[electrical:depth_of_discharge|Depth of Discharge]].  A 100Ah lead battery holds ~1,200Wh (100Ah x 12v), and one discharged to 50% holds 600Wh (1,200Wh x 0.5).  It would take **166Ah of lead** battery to give us 1,000Wh usable. +  * lead-chemistry batteries (FLA, AGM, GEL) are typically [[electrical:nominal|nominal]] 12v and discharged to 50% [[electrical:depth_of_discharge|Depth of Discharge]].  A 100Ah lead battery holds ~1,200Wh (100Ah x 12v), and one discharged to 50% holds 600Wh (1,200Wh x 0.5).  It would take **166Ah of lead** battery to give us 1,000Wh usable. (1,000Wh / 600Wh = 1.66 100Ah batteries) 
-  * lithium batteries are typically nominal 12.8v and discharged to 80% DoD.  A 100Ah LFP battery holds 1,280Wh, of which 1,024Wh are usable (1,280Wh x 0.8).  It would take **98Ah of LFP** to give us 1,000Wh usable.  +  * lithium batteries are typically nominal 12.8v and discharged to 80% DoD.  A 100Ah LFP battery holds 1,280Wh, of which 1,024Wh are usable (1,280Wh x 0.8).  It would take **98Ah of LFP** to give us 1,000Wh usable.  (1,000Wh / 1,024Wh = ~0.98 100Ah batteries)
  
  
Line 40: Line 42:
  
  
-==== charging predictability ====+==== charging  ==== 
 + 
 + 
 +=== charging stability and predictability ===
  
  
Line 51: Line 56:
   * solar charging is highly unpredictable, being greatly affected by weather and [[electrical:solar:output|other factors]].  Rigs with solar-only charging may have to plan for days of minimal harvest, or have the flexibility to reduce consumption when solar harvest is compromised.    * solar charging is highly unpredictable, being greatly affected by weather and [[electrical:solar:output|other factors]].  Rigs with solar-only charging may have to plan for days of minimal harvest, or have the flexibility to reduce consumption when solar harvest is compromised. 
  
 +=== minimum current requirements ===
 +
 +Lead chemistries typically have minimum charging current requirements to stay healthy
 +
 +  * FLA 0.10C (10A for every 100Ah of capacity)
 +  * AGM 0.20C (20A for every 100Ah of capacity)
 +
 +If we cannot meet minimums the bank should be downsized (or [[electrical:12v:alt_and_solar|charging increased]]).  
 +
 +Note:  Lithium has no minimum charging current
 +
 +
 +=== maximum charging limits ===
 +
 +Battery chemistries typically have maximum charging currents that can stress charging systems (particularly alternators via combiners):
 +
 +  * FLA 0.20C (20A for every 100Ah of capacity)
 +  * AGM 0.33C (33A for every 100Ah of capacity)
 +  * LFP 1.0C (100A for every 100Ah of capacity)
 +
 +If the alternator can only safely provide 50A of charging to the house bank this would limit us to a 166Ah AGM bank (166Ah x 0.33 = 50A). If the alternator has excess capacity then a larger bank can accept more current.  This doesn't mean the bank would get full any faster((it's larger, after all)) but you will gather more Ah/Wh on any given run. 
  
  
  
  