| ===== must I use the PS brand's proprietary solar panels? ===== | ===== must I use the PS brand's proprietary solar panels? ===== |
| |
| No, you can use any panel that meets the PS' requirements. Consult the power station's [[lifestyle:faq_solar_generator#solar_charging_limits|solar ("PV") input specs]] and buy panel[s] whose [[electrical:solar:panels#specifications|output specs]] are within the the stated limits of the PS' internal [[electrical:solar:charge_controller|solar charge controller]]. For the purposes of this section we will use these actual input specs for reference: | No, you can use any panel that meets the PS' requirements. Consult the power station's [[lifestyle:faq_solar_generator#solar_charging_limits|solar ("PV") input specs]] and buy panel[s] whose [[electrical:solar:panels#specifications|output specs]] are within the PS' limits. This will ensure that the PS' internal [[electrical:solar:charge_controller|solar charge controller]] is not damaged by overvoltage. For the purposes of this section we will use these actual input specs for reference: |
| |
| ''12v-45v, 10A'' | ''12v-45v, 10A'' |
| * 40Vmp x 10A = 400w | * 40Vmp x 10A = 400w |
| |
| | So a general rule of thumb to get the most power out of panel + SG combo is to select panels that will (by themselves or when arranged in series) have a Voc toward((not //at//)) the upper end of the PS' input limit. This will place the Vmp as high up in the input voltage range as practical without going over. |
| Sometimes no current limit is stated and we have to back into it. In our case the 500w will be attainable at at 45v, suggesting the current limit is 11.11A (500w / 45v). Remember the panel's Voc cannot exceed 45v so we cannot really run a 45Vmp panel.((Voc is always > Vmp, typically by ~20%)) | |
| ==== can I overpanel my power station? ==== | ==== can I overpanel my power station? ==== |
| |