User Tools

Site Tools


electrical:12v:battery_capacity

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
electrical:12v:battery_capacity [2025/06/24 19:06]
frater_secessus [C notation]
electrical:12v:battery_capacity [2025/06/24 19:12] (current)
frater_secessus [C notation]
Line 6: Line 6:
  
  
-Note:  most deep cycle manufacturer's rate capacity at C/20, due to Peukert effect on lead chemistries (see below).((Lithium doesn't not have a significant Peukert effect.  Capacity measured by C/20 and by amp-counting will be nearly identical)).  In other words, a 100Ah battery will deliver 100A with a 5A load over 20 hours. +Note:  most deep cycle manufacturer's rate capacity at C/20 (0.05C), due to Peukert effect on lead chemistries (see below).((Lithium doesn't not have a significant Peukert effect.  Capacity measured by C/20 and by amp-counting will be nearly identical)).  In other words, a 100Ah battery will deliver 100A with a 5A load over 20 hours.
  
  
 ===== Examples ===== ===== Examples =====
  
-If you have 200AH battery bank then C = 200AH. +Assuming 200Ah bank:
- +
-If the manufacturer recommends max //charging// at C/5 the rate should be at or below 40A (200/5). \\  +
- +
-If the manufacturer recommends minimum charging at C/10 the rate should be at or above 20A (200/10). \\  +
- +
-If the manufacturer recommends max //discharge// (load) be 3C the rate should be at or below 600A (3x200). \\ +
  
-If the manufacturer says that [[electrical:12v:charging|Absorption stage]] is complete when charging current has dropped to C/100 or C/200 then the current to watch for would be 2A (200/100) or 1A (200/200).+  * If the manufacturer recommends max //charging// at 0.2C the rate should be ≤40A (200 x 0.2) 
 +  * If the manufacturer recommends minimum charging at C110 the rate should be ≤20A (200 x 0.1) 
 +  * If the manufacturer recommends max //discharge// (load) be 3C the rate should be ≤600A (200 x 3) 
 +  * If the manufacturer says that [[electrical:12v:charging|Absorption stage]] is complete when charging current current has dropped to ≤0.05C then the current to watch for would be ≤10A (200 x 0.05)
  
 ===== other than 20hr rates ===== ===== other than 20hr rates =====
electrical/12v/battery_capacity.1750792006.txt.gz · Last modified: 2025/06/24 19:06 by frater_secessus