electrical:12v:battery_capacity
Differences
This shows you the differences between two versions of the page.
Both sides previous revision
Previous revision
Next revision
|
Previous revision
|
electrical:12v:battery_capacity [2025/06/24 19:06] frater_secessus [C notation] |
electrical:12v:battery_capacity [2025/06/24 19:12] (current) frater_secessus [C notation] |
| |
| |
Note: most deep cycle manufacturer's rate capacity at C/20, due to Peukert effect on lead chemistries (see below).((Lithium doesn't not have a significant Peukert effect. Capacity measured by C/20 and by amp-counting will be nearly identical)). In other words, a 100Ah battery will deliver 100A with a 5A load over 20 hours. | Note: most deep cycle manufacturer's rate capacity at C/20 (0.05C), due to Peukert effect on lead chemistries (see below).((Lithium doesn't not have a significant Peukert effect. Capacity measured by C/20 and by amp-counting will be nearly identical)). In other words, a 100Ah battery will deliver 100A with a 5A load over 20 hours. |
| |
| |
===== Examples ===== | ===== Examples ===== |
| |
If you have a 200AH battery bank then C = 200AH. | Assuming a 200Ah bank: |
| |
If the manufacturer recommends max //charging// at C/5 the rate should be at or below 40A (200/5). \\ | |
| |
If the manufacturer recommends minimum charging at C/10 the rate should be at or above 20A (200/10). \\ | |
| |
If the manufacturer recommends max //discharge// (load) be 3C the rate should be at or below 600A (3x200). \\ | |
| |
If the manufacturer says that [[electrical:12v:charging|Absorption stage]] is complete when charging current has dropped to C/100 or C/200 then the current to watch for would be 2A (200/100) or 1A (200/200). | * If the manufacturer recommends max //charging// at 0.2C the rate should be ≤40A (200 x 0.2) |
| * If the manufacturer recommends minimum charging at C110 the rate should be ≤20A (200 x 0.1) |
| * If the manufacturer recommends max //discharge// (load) be 3C the rate should be ≤600A (200 x 3) |
| * If the manufacturer says that [[electrical:12v:charging|Absorption stage]] is complete when charging current current has dropped to ≤0.05C then the current to watch for would be ≤10A (200 x 0.05) |
| |
===== other than 20hr rates ===== | ===== other than 20hr rates ===== |
electrical/12v/battery_capacity.1750792006.txt.gz · Last modified: 2025/06/24 19:06 by frater_secessus