This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
electrical:12v:battery_monitor [2024/02/11 15:20] frater_secessus [drift and reset] |
electrical:12v:battery_monitor [2024/10/21 10:43] (current) frater_secessus [TL;DR] |
||
---|---|---|---|
Line 7: | Line 7: | ||
[[https:// | [[https:// | ||
* Battery monitors start from a known State of Charge then count every Amp going into or out of the battery bank | * Battery monitors start from a known State of Charge then count every Amp going into or out of the battery bank | ||
+ | * the shunt can be internal to the battery (lithium batts with BMS comms) or external to the bank | ||
+ | * the current acceptance of the battery bank in Absorption can tell you how close to fully charged a lead battery is((applies to Li also but the numbers are much smaller and we are not chasing 100% necessarily)) | ||
* these measurements can go astray (" | * these measurements can go astray (" | ||
* drift will be more noticeable with lead chemistries than lithium | * drift will be more noticeable with lead chemistries than lithium | ||
Line 25: | Line 27: | ||
Heads up: there are // | Heads up: there are // | ||
+ | |||
+ | ===== sizing ===== | ||
+ | |||
+ | The shunt should be sized to handle your highest expected demand comfortably. For example, a system designed for 80A of current would work well with a 100A shunt. | ||
+ | |||
+ | A shunt that is **too small** a shunt will fail if exposed to current that exceeds its rating. | ||
+ | |||
+ | A shunt that is **too large** presents different problems. | ||
+ | |||
+ | |||
===== how they work ===== | ===== how they work ===== | ||
Line 39: | Line 51: | ||
Small problems accrue over time, reducing the monitor' | Small problems accrue over time, reducing the monitor' | ||
- | * the **measurement can be inaccurate** because current is very low (<1A) or very high (the monitor' | + | * the **measurement can be inaccurate** because current is very high or low relative to the shunt' |
* the measurement and counting is **accurate but is not reliable for estimating changes in state of charge**. | * the measurement and counting is **accurate but is not reliable for estimating changes in state of charge**. | ||
* or a combination of the above | * or a combination of the above | ||
- | For those reasons the monitor | + | For those reasons |
+ | |||
+ | - automatically by the monitor when a certain voltage setpoint is achieved.((14.0v = 100%, for example)) | ||
+ | - manually by the user. For practical reasons | ||
One rule of thumb is to reset the monitor 1x/ | One rule of thumb is to reset the monitor 1x/ | ||
Line 67: | Line 82: | ||
[[https:// | [[https:// | ||
- | The 500A SmartShunt is available in [[https:// | + | The 500A SmartShunt is available in [[https:// |
Both setups can provide voltage, current, and temperature information to the app or directly to other Victron gear like solar charge controllers.((the Orion-TR is a notable and much-lamented exception)) | Both setups can provide voltage, current, and temperature information to the app or directly to other Victron gear like solar charge controllers.((the Orion-TR is a notable and much-lamented exception)) | ||
+ | * YT: [[https:// | ||
==== Bogart Trimetric ==== | ==== Bogart Trimetric ==== | ||
Line 107: | Line 122: | ||
By default the backlight is ON when discharging and FLASHING((slow pulsing)) when charging. | By default the backlight is ON when discharging and FLASHING((slow pulsing)) when charging. | ||
+ | |||
+ | == quirks == | ||
+ | |||
+ | The decimal point is small and moves as numbers increase. | ||
+ | |||
+ | |||
+ | * 1**.**234A (also 0.123A) | ||
+ | * 12**.**34A | ||
+ | * 123**.**4A | ||
=== Renogy === | === Renogy === | ||
Line 117: | Line 141: | ||
=== other examples === | === other examples === | ||
- | [[https:// | + | [[https:// |
Heavier-duty shunts are available (up to [[https:// | Heavier-duty shunts are available (up to [[https:// |