electrical:12v:directcharginglfp [2025/03/18 13:12]
frater_secessus [current drawn expressed as C-rate] paribus
electrical:12v:directcharginglfp [2025/03/28 16:27] (current)
frater_secessus [failures]
Line 119: Line 119:
 === lessons === === lessons ===
  
-  -  Think twice about  direct-charging banks that have 2-3x the capacity of your alternator's rating.   If you need to do this use [[electrical:12v:b2b|DC-DC charger]], external regulation, or current reduction with resistance as described elsewhere in this article.+  -  Think twice about  direct-charging banks that have 2-3x the capacity of your alternator's rating.   If you need to do this use a **properly-sized** [[electrical:12v:b2b|DC-DC charger]], external regulation, [[electrical:12v:alternator_details#thermal_switches|thermal switches]], current reduction with resistance as described elsewhere in this article, etc
   - do not idle to charge.    - do not idle to charge. 
  
electrical/12v/directcharginglfp.txt ยท Last modified: 2025/03/28 16:27 by frater_secessus