This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
electrical:12v:renogy_dip_switches [2024/09/02 14:37] frater_secessus [float] |
electrical:12v:renogy_dip_switches [2024/09/02 15:16] (current) frater_secessus [TL;DR] |
||
---|---|---|---|
Line 1: | Line 1: | ||
+ | DRAFT - please report errors | ||
+ | |||
+ | |||
====== DIP switches on Renogy DC-DC chargers ====== | ====== DIP switches on Renogy DC-DC chargers ====== | ||
===== TL;DR ===== | ===== TL;DR ===== | ||
+ | |||
+ | * the DIP configuration tables and nomenclature in [[https:// | ||
+ | * the DIP switch area has indicator that shows '' | ||
+ | * in the tables below, lithium (Li) profiles effectively means " | ||
+ | |||
+ | ([[opinion: | ||
===== profiles without float (lithium chemistries) ===== | ===== profiles without float (lithium chemistries) ===== | ||
+ | |||
^ Li Boost voltage | ^ Li Boost voltage | ||
Line 15: | Line 25: | ||
^ 13.0v | OFF | OFF | OFF | ON | OFF | | ^ 13.0v | OFF | OFF | OFF | ON | OFF | | ||
+ | An [[electrical: | ||
===== profiles with float (lead chemistries) ===== | ===== profiles with float (lead chemistries) ===== | ||
Line 20: | Line 31: | ||
- | ^ Pb Boost voltage | + | ^ Pb Boost voltage |
- | ^ LiFePO4 | + | ^ 14.1v((gel? |
- | ^ LiFePO4 14.2v | + | ^ 14.4v((AGM?)) | ON | ON |
- | ^ LiFePO4 | + | ^ 14.7v((flooded?)) | OFF | OFF | | | ON | |
- | ^ LiFePO4 14.6v((not recommended - secessus)) | ON | ON | ON | ON | OFF | | + | |
- | ^ | + | |
- | ^ 12.6v((3S Li-NMC, for example)) | OFF | OFF | OFF | OFF | + | |
- | ^ 12.8v | OFF | OFF | + | |
- | ^ 13.0v | OFF | OFF | OFF | ON | OFF | + | |
==== float ==== | ==== float ==== | ||
+ | ^ Pb Float voltage | ||
+ | ^ 13.2v | ||
+ | ^ 13.5v | ||
+ | ^ 13.8v | ||
+ | |||
+ | ===== using a lead profile to float Li ===== | ||
+ | |||
+ | There are reasons for and against [[electrical: | ||
+ | |||
+ | Renogy Li profiles are charge-and-stop: | ||
+ | |||
+ | - charge to the selected Boost setpoint | ||
+ | - stop charging | ||
+ | - drift down to the reBoost setpoint, typically 13.2v,if loads are present | ||
+ | - start the charging cycle again | ||
+ | |||
+ | If you want to //hold// a 13.2v floor instead of cycling repeatedly you might charge use a Pb profile to charge to 14.1v((the lowest available)) and " | ||
+ | |||
+ | A 13.8V float is unacceptably high((IMO - secessus)); | ||
+ | |||
- | ^ Pb Float voltage | ||
- | ^ LiFePO4 14.0v | OFF | OFF | ON | ON | OFF | | ||
- | ^ LiFePO4 14.2v | ON | OFF | ON | ON | OFF | | ||
- | ^ LiFePO4 14.4v | OFF | ON | ON | ON | OFF | | ||
- | ^ LiFePO4 14.6v((not recommended - secessus)) | ||
- | ^ | | | | | | | ||
- | ^ 12.6v((3S Li-NMC, for example)) | ||
- | ^ 12.8v | OFF | OFF | ON | OFF | OFF | | ||
- | ^ 13.0v | OFF | OFF | OFF | ON | OFF | | ||