| - | ====== smart chargers ====== | ||
| - | |||
| - | Words of wisdom: | ||
| - | |||
| - | Smart chargers, whether solar charge controllers or shore power chargers, use **three stages** to charge lead-acid batteries. | ||
| - | |||
| - | - **bulk** - **maximum amps** are dumped into the battery until it reaches acceptance voltage (~14.2v)((http:// | ||
| - | - **acceptance** (or absorption) - the **voltage is held steady** until amps drop below a defined rate at which time it is considered charged | ||
| - | - **float** (or maintenance) - the charged battery is held at ~13.2v indefinitely | ||
| - | - some may also include a fourth " | ||
| - | |||
| - | In some chargers these voltages and other setpoints can be configured by the user to better match battery maker recommendations, | ||
| - | |||
| - | ===== temperature and charging ===== | ||
| - | |||
| - | Accurate charging requires the charger know the temperature of the batteries being charged. | ||
| - | |||
| - | |||
| - | ===== equalization ===== | ||
| - | Flooded lead-acid batteries can, over time and in certain conditions, end up with stratified electrolyte. | ||
| - | |||
| - | Note that equalization is usually done with house circuits disconnected as the overvoltage might confuse or damage electronics. | ||