Line 34: | Line 34: | ||
* since rated wattage is 100w, the cells //must// be 5.55Isc (amps at max power); | * since rated wattage is 100w, the cells //must// be 5.55Isc (amps at max power); | ||
- | For reasons discussed below the string of 36 cells will be subdivided into substrings of cells in series. | + | For reasons discussed below the string of 36 cells will be subdivided into substrings of cells in series. |
- | ############ | + | ######### |
- | | + | |
- | | + | |
+ | | ||
| | ||
- | as | + | straightened out but electrically identical |
- | ############ | + | ################## |
| | ||
Line 51: | Line 52: | ||
==== partial shade is bad for panels ==== | ==== partial shade is bad for panels ==== | ||
- | * power moves in the direction of higher voltage to lower voltage. | + | |
- | * when shaded sufficiently any given cell's voltage will drop off sharply((" | + | * when shaded sufficiently any given cell's voltage will drop off sharply((" |
- | * so power from neighboring cells moves //into// the cell instead of out of it | + | * so power from neighboring cells moves //into// the cell instead of out of it |
- | * the cell converts this power into heat which can damage or destroy the cell, or catch the panel on fire | + | * the cell converts this power into heat which can damage or destroy the cell, or catch the panel on fire |
- | When the entire panel is lit or shaded evenly | + | When the entire panel is lit or shaded evenly |
Line 62: | Line 63: | ||
==== so panel designers try to limit damage ==== | ==== so panel designers try to limit damage ==== | ||
- | We can't stop the cell voltage from collapsing in shade so we need a way to remove it, electrically, | + | We can't stop the cell voltage from collapsing in shade so we need a way to remove it, electrically, |
+ | |||
+ | Right now we are concerned with the interatctions of panel internals so we are talking about //bypass diodes// | ||
+ | |||
+ | Simplest example: | ||
+ | |||
+ | But diodes for each cell would be more expensive in components, assembly, and design. | ||
+ | | ||
+ | ################## | ||
+ | |||
+ | ...where the equal sign (" | ||
+ | |||
+ | |||
+ | Real-world example: we have two substrings, each with 18 cells ins series. | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | In partial shade one of the cells in the 2nd substring are affected. | ||
+ | |||
+ | | ||
+ | ################## | ||
+ | |||
+ | If their were no diodes we would have 9v from the 1st string and 7.5v from the 2nd string for a total of 16.5v. But the shaded cells in the 2nd string would overheat. So it is bypassed and now the panel makes **9v**. | ||
+ | |||
+ | **Oops**: | ||
+ | |||
+ | **Thought experiment: | ||
+ | |||
- | ==== which has observable effects on output ==== | ||
Line 71: | Line 100: | ||
==== so users try different panel configurations ==== | ==== so users try different panel configurations ==== | ||
+ | === parallel === | ||
+ | Let's start using both our panels in parallel | ||
+ | ######### | ||
+ | ######### | ||
+ | ######### | ||
+ | ######### | ||
+ | |||
+ | ######### | ||
+ | ######### | ||
+ | ######### | ||
+ | ######### | ||
+ | |||
+ | which, unwound and with bypass diodes, would be | ||
+ | |||
+ | | ||
+ | ################## | ||
+ | | ||
+ | | ||
+ | ################## | ||
+ | |||
- | **Before | + | if we have the same partial |
- | Partial | + | |
- | * light is falling on the panel | ||
- | * but not evenly on the panel -- it is different on some cells | ||
- | To prevent power from rushing into the shaded string and overheating them, panels have bypass diodes between the strings. | + | |
+ | | ||
+ | ################## | ||
+ | |||
+ | | ||
+ | ################## | ||
+ | |||
+ | |||
+ | |||
+ | To prevent voltage backing up into a panel from a neighboring panel (or battery bank at night) each //panel// typically has a //blocking diode//. So the complete picture is: | ||
+ | | ||
+ | ################## | ||
+ | | ||
+ | | ||
+ | ################## | ||
+ | Note: in most panels the blocking and bypass diodes are identical parts, just installed in different places, in different orientations, | ||
+ | |||
+ | |||
+ | |||
+ | === series === | ||
+ | | ||
+ | | ||
+ | ################## | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | | ||
+ | | ||
+ | | ||
+ | | ||
+ | | ||