| === solar charging limits === | === solar charging limits === | ||
| + | |||
| + | also see [[12v: | ||
| Many smaller units have quite restrictive solar input limits. | Many smaller units have quite restrictive solar input limits. | ||
| - | * **voltage** - 22Voc is a common voltage limit, effectively limiting one to [[electrical: | + | * **voltage** - 24Voc is a common voltage limit, effectively limiting one to [[electrical: |
| - | * **current** limit - 3A is a common input current limit on smaller, less-expensive units. | + | * **current** limit - 3A is a common input current limit on smaller, less-expensive units. |
| - | * With PWM controllers the max power harvestable will be 3A x [internal battery voltage], which can be as low as 9v. 9v x 3A 27w. | + | * With PWM controllers the max power harvestable will be 3A x [internal battery voltage], which can be as low as 9v. 9v x 3A 27w. |
| - | * MPPT controllers with the same limit might run the panels at 18v, the Vmp: 18v x 3A = 54w((minus DC-DC conversion losses of ~5%)) | + | * MPPT controllers with the same limit might run the panels at 18v, the Vmp: 18v x 3A = 54w((minus DC-DC conversion losses of ~5%)) |
| + | |||
| + | == the Amp bottleneck == | ||
| + | |||
| + | Because the Amp limit is usually the limiting factor for MPPT power production. | ||
| + | |||
| + | * 22.5Voc panel - Vmp ~18v.((Vmp is typically 0.8 of Voc)) 18v x 8A limit = **144w**. | ||
| + | * 21Voc panel - Vmp ~16.8v. | ||