===== issues ===== | ===== issues ===== | ||
+ | |||
+ | [[rv: | ||
+ | |||
They may not be a fit for all use cases, though. | They may not be a fit for all use cases, though. | ||
Line 16: | Line 19: | ||
* the **MPPT algorithm** is not particularly robust | * the **MPPT algorithm** is not particularly robust | ||
- | * it will adjust to changing conditions, but it can be slow | + | * it will adjust to changing conditions, but it can be slow. One might say " |
* it can be slow to react after long periods of no load - see [[https:// | * it can be slow to react after long periods of no load - see [[https:// | ||
- | * it can get confused in complex solar conditions, as with partly-cloudy skies and high winds, or in breezes that move partial shade around on the panels. | + | * it can get confused in complex solar conditions, as with partly-cloudy skies and high winds, or in breezes that move partial shade around on the panels. |
* the large AN controllers (≥50A) have **undersized terminal screws** which can snap under overzealous tightening. | * the large AN controllers (≥50A) have **undersized terminal screws** which can snap under overzealous tightening. | ||
+ | * firmware does not appear to be field-upgradable without hacking | ||
+ | * Absorption duration cannot be zeroed out; the minimum duration is 10 minutes. | ||
+ | * Absorption duration max is 180 minutes | ||
+ | |||
+ | ==== tracking crashes ==== | ||
+ | |||
+ | === videos === | ||
+ | |||
+ | |||
+ | * [[https:// | ||
+ | * [[https:// | ||
+ | * [[https:// | ||
+ | |||
+ | |||
+ | === anecdotes === | ||
+ | |||
+ | |||
+ | |||
+ | >> My epever often pulls pv voltages down to battery voltage acting like PWM. Getting really annoying now. It works okay with 12v and 17.5v panels, but the bigger panels with a voltage of 35v present a problem on cloudy days. It drags thr voltage down, and doesnt let it back up until i reset the unit. It then lets the panels back up to proper voltage and starts producing decent power again. ([[https:// | ||
+ | |||
+ | |||
+ | >> I have the 4215bn with mt50, and whenever I connect my solar panels in series (2x100w), it will display the accumulated voltage for a few seconds (40w) under the pv icon, then it will go down to between 13-20v, immediately, | ||
+ | |||
+ | >> I'm sending my tracer3215bm back today as the mppt tracking issue is a blocker for me. I have 3 60 cell panels in series for a total of around 90v pv. This is on a 24v system. One morning it will work fine and the next it will get stuck down around 28v and never increase leaving my output at a fraction of what it could be. The only way to get it to increase the pv voltage is to disconnect the pv array momentarily. | ||
+ | |||
+ | >> Facing the same with Epever (12v system) in bad conditions it will pull the 2x 18v panels in series down to single panel voltage range of 14-18v. I resorted to taking my panels in parallel (which sucks due to higher current and cable losses), which wastes less. In northern europe this is a killer for my batteries in winter, as i cannot even maintain a proper float voltage with my equipment attached. ([[https:// | ||
+ | |||
+ | >> The system seems to work as it should most of the time. On occasion in full sun the charge controller shows a lower voltage ie 26.4 v about half of what it typically does in full sun. If I unplug everything and plug the panels back in it will return to the higher voltage around 60v and begin working normally again. ([[https:// | ||
+ | |||
+ | |||
+ | >> | ||
+ | |||
+ | |||
+ | >> | ||
+ | |||
+ | >> I have 2 3210AN and one of them have the same problem.. need to disconnect to PV and need 3-5 second to track correctly. it's cause 8% less energy production compare to another one. - [[https:// | ||
+ | |||
+ | |||
+ | >> I have 3210AN and the same problem. I only have one panel Risen 440Wp Vmpp 43.8V. In the morning or in the cloudy sky Mppt does not work. Holds 14V about 24W. When disconnected it goes on about 43V and shows 100W. This is annoying. This is evident software error. -- [[https:// | ||
+ | |||
+ | >> im having the same issue with epever charge controller. Early morning before the sun fully hits the panels 17 volts and .5 amps from a 60 volt array 300 watt array. I can unplug the panels and reconnect at it goes up to 57 or so volts then slowly drifts back to 17 again. Does the tracking just not work right or what is your opinion. I ran 2 100 watt 18.9 vmp panels on the epever. And 2 on a pwm. The mppt would go from 150 watts in full sun to 100 watt output every 20 minutes or so. And the pwm would steady put out 148 watts. In an all day comparison pwm won producing more watt hours.((https:// | ||
+ | >> I threw out my EPSolar Tracers for the same reason, equal paneling with correct voltages in a test of 3 EP Solar Tracers verses 3 Trace C-40 PWM The old trace units preformed much better. ... [the epever] would slowly sink in PV input volts until reset or maybe 20-30 minutes later would do a full sweep and come up to a decent input voltage. I bought a Classic.....problems gone((https:// | ||
+ | >> After driving with the Victron DC-DC charger kicking on, the Epever MPPT solar charge controller would act similar to a PWM controller: it would read incoming voltage close to the battery' |