This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
opinion:frater_secessus:mppt_anthills [2025/08/06 15:47] frater_secessus [the basic situation] |
opinion:frater_secessus:mppt_anthills [2025/08/06 16:10] (current) frater_secessus [multiple (known) anthills of varying heights] |
||
---|---|---|---|
Line 18: | Line 18: | ||
{{ https:// | {{ https:// | ||
- | This is like having one panel or multiple identical panels on the same MPPT. There is one anthill (one power curve, the blue line in the image)) and one highest point on that anthill (**M**aximum **P**ower **P**oint on the curve). | + | This is like having one panel or multiple identical panels on the same MPPT. There is one anthill (one power curve, the blue line in the image) and one highest point on that anthill (**M**aximum **P**ower **P**oint on the curve). |
==== multiple anthills (unknown) of varying heights ==== | ==== multiple anthills (unknown) of varying heights ==== | ||
Line 24: | Line 24: | ||
Unbeknownst to you there are really // | Unbeknownst to you there are really // | ||
- | This is like having mixed panels on the same MPPT controller. | + | This is like having mixed panels on the same MPPT controller. |
Line 31: | Line 31: | ||
If they tell you in advance there may be many different anthills you can explore the entire field and remember each hill you find. Eventually you will find the tallest one. | If they tell you in advance there may be many different anthills you can explore the entire field and remember each hill you find. Eventually you will find the tallest one. | ||
- | This is what happens when you use an MPPT with an advanced algorithm that makes full sweeps of the I/V curve instead of looking only for local high spots. | + | This is what happens when you use an MPPT with an advanced algorithm that makes full sweeps of the power curve instead of looking only for local high spots. |
* the controller generally costs more upfront | * the controller generally costs more upfront | ||
Line 37: | Line 37: | ||
* and more time to //keep checking for the max// along the whole curve. | * and more time to //keep checking for the max// along the whole curve. | ||
- | During these extended sweeps harvest falls off dramatically because the algo has to check the whole I/V curve, including points that make little-to-no power. | + | During these extended sweeps harvest falls off dramatically because the algo has to check the whole curve, including points that make little-to-no power. |
This algorithm will find the MPP of the mismatched array but cannot make as much power as different panels/ | This algorithm will find the MPP of the mismatched array but cannot make as much power as different panels/ |