Table of Contents

Series and Parallel solar arrays

TL;DR

Series

Series arrays are used to generate higher voltages to feed the controller.

Parallel

Series-Parallel

Consider this scenario:

A fully-series configuration (1p4s) would have a Voc of 91.2v, greatly exceeding the controller's input spec of 60v, and it's common to want to have 20% voltage headroom above Voc.

A fully-parallel configuration (4p1s) would require 3x 2-into-1 MC4 adapters or 1x 4-into-1 adapter. The wiring from the array would need to carry 30A+ to the controller, necessitating heavier wiring that would cost more and might not even fit the controller terminals. It might be unable to charge at all under extreme low-light conditions.

A compromise might be series-parallel array (2p2s) with 45.6Voc and ~16A. This would require 1x 2-into-1 MC4 adapter to combine the two serial strings. Voltage is low enough for the controller, but high enough to allow low-light charging and the use of lighter wiring.

further reading