Table of Contents

patterns in solar harvest

unscientific terms

In my case, Rated is 570w and MPPT theoretical is 467w.

observations

Overpaneled configurations (relatively high panel watt to battery Ah ratio) tend have two main features:

  1. improved charging in adverse conditions
  2. apparent low output in normal conditions - this occurs because the batteries are typically in Absorption with battery charging demand dropping by solar noon; there is rarely an opportunity to demonstrate full output.

correlation with available direct light

This is harder to grasp and compute, but increases accuracy by factoring in location, time, etc.1)

  1. find solar zenith angle with app or calculator
  2. derive cosine of the above; this is the percentage of direct sunlight landing on a flat surface
  3. multiply this value by panel wattage
  4. the result is the theoretical direct light available at that time/place under clear skies.2)

I have observed the following cosine-based direct light percentages:

ununsual scenarios

1)
It cannot account for indirect light by refraction, reflection,etc. The contribution of indirect light is considered to be +15% in clear skies.
2)
since MPPT-based system losses typically are -15% and indirect lighting is +15%, an MPPT-based system might make this direct-light power level under clear skies.
3)
before I increased array to 750w