electrical:12v:alternator [2024/04/09 14:41]
frater_secessus [limitations] timing
electrical:12v:alternator [2024/04/16 11:31]
frater_secessus [disabling alternator charging] delay
Line 569: Line 569:
 It may be desirable to disable alternator charging on-the-fly when stopped in traffic, on hot days, to avoid charging frozen Li cells,((using a temperature controller)) stop charging at a given voltage,((using a [[electrical:12v:alternator_charging_hvd|High Voltage Disconnect]])) or neutralize [[electrical:12v:alternator#gotchas|gotchas]], etc.  The method of disabling will vary depending on the gear: It may be desirable to disable alternator charging on-the-fly when stopped in traffic, on hot days, to avoid charging frozen Li cells,((using a temperature controller)) stop charging at a given voltage,((using a [[electrical:12v:alternator_charging_hvd|High Voltage Disconnect]])) or neutralize [[electrical:12v:alternator#gotchas|gotchas]], etc.  The method of disabling will vary depending on the gear:
  
-  * relays and DC-DC that are triggered solely by D+ can be disabled by a switch on the D+ wire+  * relays and DC-DC that are triggered solely by D+ can be disabled by a switch on the D+ wire.  [[https://www.reddit.com/r/VanLife/comments/1c4vjl0/is_this_renogy_a_good_dcdc_option_for_a_200ah/kzuc78v/|Additional control could be introduced]] with a relay and or delay ([[https://amzn.to/3TUEbmu|example]])
   * VSR triggered by voltage can can be disabled by a switch on the thin ground wire on the VSR itself.((the VSR requires a ground to make a complete circuit to run internal electronics.  Breaking this circuit turns off the  VSR))     * VSR triggered by voltage can can be disabled by a switch on the thin ground wire on the VSR itself.((the VSR requires a ground to make a complete circuit to run internal electronics.  Breaking this circuit turns off the  VSR))  
   * some DC-DC can be //derated// by providing a 12v signal to the CURRENT LIMIT terminal ([[electrical:12v:b2b#renogy1|Renogy DC1212 series]], [[electrical:12v:b2b#leaptrend|Leaptrend]])   * some DC-DC can be //derated// by providing a 12v signal to the CURRENT LIMIT terminal ([[electrical:12v:b2b#renogy1|Renogy DC1212 series]], [[electrical:12v:b2b#leaptrend|Leaptrend]])
electrical/12v/alternator.txt ยท Last modified: 2024/04/26 17:11 by frater_secessus