+ | == GM == | ||
+ | Information is limited, but GM factory dual alt setups appear to run the way one would expect in the first place, with load shared between them: | ||
+ | |||
+ | > The two alternators are controlled over a common circuit from the ECM so they cannot be controlled independently. The ECM cannot shut one down and let the other one run. It is both or neither. | ||
+ | ((https:// | ||