Line 1: Line 1:
-Note:  this is for deep cycle lead chemistries only.!  Lithium chemistries should not be held at full voltage. +Note:  this is for deep cycle lead chemistries only!  Lithium batteries should not be held at full voltage. 
  
-====== insufficient Absorption ====== 
  
-In off-grid solar charging scenarios batteries are most often damaged by [[electrical:batterycide|chronic undercharging]].  Specifically, not holding the [[electrical:solar:charge_controller_setpoints|manufacturer'recomended Absorption voltage]] (Vabs), and not holding that voltage long enough((duration)) for acceptance to drop to endAmps.+[[lifestyle:words_of_wisdom|Words of wisdom]]: 
 + 
 +> "As long as... you cycle the battery daily, you could set float voltage to [Vabs] too without worry. Only when you stop cycling the battery do you need to return float voltage to more regular 13.2v levels." -- sternwake((http://www.cheaprvliving.com/forums/showthread.php?tid=20022&pid=229883#pid229883)) 
 + 
 + 
 +====== dealing with insufficient Absorption ====== 
 + 
 +In off-grid solar charging scenarios batteries are most often damaged by [[electrical:batterycide|chronic undercharging]].  Specifically, not holding the [[electrical:solar:charge_controller_setpoints|manufacturer'recommended Absorption voltage]] (Vabs), and not holding that voltage long enough((duration)) for acceptance to drop to endAmps.
  
 Causes of insufficient Absorption: Causes of insufficient Absorption:
Line 11: Line 17:
   * solar conditions - not enough good sun long enough to finish Absorption   * solar conditions - not enough good sun long enough to finish Absorption
  
-===== set Vfloat to Vabs =====+===== workarounds  ===== 
 + 
 +While you may not be able to increase the //actual// duration,((as when the controller setpoint is maxxed out)) you can achieve a similar effect with one or more of these techniques:  
 + 
 + 
 +  * if duration setpoint is maxxed then **set Vfloat == Vabs**.  Absorption duration will effectively be "until the sun goes down"
 +  * **charge at a lower current** (charging minimum).  While [[opinion:frater_secessus:charging_faster|overall charging will take about the same amount of time]], Bulk's share of that time will increase and [[electrical:12v:charging#absorption|Absorption will take somewhat less time]]. 
 +  * **Absorb at a higher((but still manufacturer-sanctioned)) voltage** (Vabs), this will decrease Absorption duration.  Keep a close watch on water levels for flooded batts, and also mind the max allowable voltage for AGM/Gel. 
 +  * **Float at a higher((but still manufacturer-sanctioned)) voltage** (Vfloat).   
 +  * [[electrical:12v:alt_and_solar|supplement]] solar charging with another charging source during Bulk, allowing more time for solar to finish absorption. 
 + 
 + 
 + 
 + 
 + 
 + 
 +Some controllers/chargers have a "restart Absorption" option allows one to override Float and get more time at Vabs.  Best use of this feature would be to look at the controller display a few minutes before the Absorption timer is due to expire.  If acceptance is good let it go.  If acceptance is too high give the bank another round of Absorption. 
  
-The Eternal Absorption approach completely forgoes Float stage, forcing the controller to stay in Absorption by setting Vfloat to Vabs. This addresses the controller issues above.+If those approaches are insufficient, //Eternal Absorption// approach completely forgoes Float stage, forcing the controller to stay in Absorption by **setting Vfloat to Vabs**. This addresses the controller issues above.  It will not address the insolation problem on a given day, but extended Absorption will help reduce damage from previous days of poor harvest
  
  
Line 25: Line 47:
 ===== gotchas ===== ===== gotchas =====
  
-  * increased Vabs duration will require more frequent watering, due to increased outgassing+  * increased Vabs duration may require more frequent watering, due to increased outgassing.((but see [[http://bdp.mousetrap.net/index.php/2020/09/18/watered-batteries-after-three-weeks-of-eternal-absorption/|this blog post]] which suggests no dramatic increase))   
 +  * calcium-enhanced batteries (typically starter batteries and some hybrid "marine" batteries) can be damaged((positive grid corrosion)) by long periods of excess voltage.    The question is which is worse for them:  chronic undercharging or grid corrosion from higher voltage.  Pick your poison.
  
  
electrical/12v/eternal_absorption.txt · Last modified: 2021/05/05 11:04 by frater_secessus