   * not charging at [[electrical:solar:charge_controller_setpoints|manufacturer-recommended Absorption voltage]] (Vabs) to reverse normally-occurring ("soft") sulfation. This is most commonly caused by [[electrical:12v:alternator|isolator-only]] charging since the house bank is being charged at ((or slightly below)) alternator voltage. \\ Less commonly, [[electrical:solar|Solar]]-only charging can cause this problem if the [[electrical:solar:sizing|battery capacity is too great for the solar output]].((http://support.rollsbattery.com/support/solutions/articles/5964-battery-sulfation))   * not charging at [[electrical:solar:charge_controller_setpoints|manufacturer-recommended Absorption voltage]] (Vabs) to reverse normally-occurring ("soft") sulfation. This is most commonly caused by [[electrical:12v:alternator|isolator-only]] charging since the house bank is being charged at ((or slightly below)) alternator voltage. \\ Less commonly, [[electrical:solar|Solar]]-only charging can cause this problem if the [[electrical:solar:sizing|battery capacity is too great for the solar output]].((http://support.rollsbattery.com/support/solutions/articles/5964-battery-sulfation))
   * not holding Vabs for [[electrical:severe_battery_use#increasing_effective_absorption_duration|sufficient duration]] so that absorption current drops to manufacturer-recommended levels. [[electrical:generator#charging_batteries|Generator-]] or  [[electrical:12v:b2b|DC-DC charging]] can cause this unless the charger runs the necessary number of hours it takes to complete Absorption.     * not holding Vabs for [[electrical:severe_battery_use#increasing_effective_absorption_duration|sufficient duration]] so that absorption current drops to manufacturer-recommended levels. [[electrical:generator#charging_batteries|Generator-]] or  [[electrical:12v:b2b|DC-DC charging]] can cause this unless the charger runs the necessary number of hours it takes to complete Absorption.  
-  * discharging too deeply.  Maximum discharge is typically limited to 50% [[electrical:depth_of_discharge|depth of discharge]].+  * discharging too deeply.  Discharge with lead-chemistries is typically limited to 50% [[electrical:depth_of_discharge|depth of discharge]] as a compromise between cycle life and bank size 
   * allowing the cells to get low on distilled water.  Check them 1x/month or so until you learn their personality.   * allowing the cells to get low on distilled water.  Check them 1x/month or so until you learn their personality.
  
Line 35: Line 35:
  
   * overvoltage.  [[electrical:12v:lifepo4_batteries_thread|13.8v is a safe upper limit]] without BMS and will charge the bank completely.  Some experienced folk use slightly higher voltages for faster charging but it must be terminated quickly as the bank approaches 100% state of charge.  Exception:  Lithium banks with BMS typically overcharge intentionally to balance cells.  The overcharge is consumed by resistors and does not actually go into the cell.     * overvoltage.  [[electrical:12v:lifepo4_batteries_thread|13.8v is a safe upper limit]] without BMS and will charge the bank completely.  Some experienced folk use slightly higher voltages for faster charging but it must be terminated quickly as the bank approaches 100% state of charge.  Exception:  Lithium banks with BMS typically overcharge intentionally to balance cells.  The overcharge is consumed by resistors and does not actually go into the cell.  
-  * long periods of 100% state of charge;  cease all charging at 100% and only charge that high if you know some loads will be applied immediately.  Lithium chemistries do not care about partial state of charge so use that to your advantage.+  * long periods of 100% state of charge;  cease all charging at 100% and only charge that high if you know some loads will be applied immediately.   
 +    * IF you're storing the van or know you're not going to be using the batteries for more than a couple days, it's strongly recommended to leave lithium batteries at 50-80% SOC. Lithium chemistries do not care about partial state of charge, and actually prefer it..
   * exposure to high heat   * exposure to high heat
   * attempting to charge at below freezing   * attempting to charge at below freezing