 Generators //are// well suited to charging [[electrical:12v:deep_cycle_battery#lithium_chemistries|lithium-chemistry batteries]] as that type can take current at all points of charging. Generators //are// well suited to charging [[electrical:12v:deep_cycle_battery#lithium_chemistries|lithium-chemistry batteries]] as that type can take current at all points of charging.
 +
 +If you are considering a genny for use with an inverter/charger combo, consider this:
 +
 +> Inverter chargers generally prefer conventional generator and not inverter generators. This is because they control the amount of power they pull from the generator just adjusting your island frequency. Inverter generators do not handle an external actor trying to adjust the frequency and will rigidly keep 50 or 60Hz until they trip. -- therealrimwarren((https://www.reddit.com/r/SolarDIY/comments/tv41bj/options_for_generator_on_an_off_grid_system/i381dv2/))
 ===== efficient use ===== ===== efficient use =====
 Generators generally have a minimum amount of wattage they can produce.  This means that until you hit that minimum multiple loads can be run for "free", speaking in terms of fuel consumption.  Generators generally have a minimum amount of wattage they can produce.  This means that until you hit that minimum multiple loads can be run for "free", speaking in terms of fuel consumption. 
Line 36: Line 40:
   - start the generator in the morning when batteries are most depleted and can take the most current   - start the generator in the morning when batteries are most depleted and can take the most current
   - use your heavy loads at the same time as possible, up to the practical limit of the generator   - use your heavy loads at the same time as possible, up to the practical limit of the generator
-  - shut the genny down after the battery bank reaches Vabs and let solar handle Absorption and Float stages+  - shut the genny down after the battery bank reaches Vabs and let solar handle Absorption and Float stages((Lithium banks may be efficiently charged by generator alone).
  
  