electrical:severe_battery_use [2018/03/20 15:04] frater_secessus [how low can we go?] |
electrical:severe_battery_use [2021/08/15 19:56] frater_secessus [Intentionally severe battery use] |
====== Intentionally severe battery use ====== | ====== Intentionally severe battery use ====== |
| |
Lead-acid chemistries prefer light cycling and full recharge between those cycles. Infrequent excursions below the [[electrical:depth_of_discharge|50% depth of discharge]] norm will not cause much damage assuming a full charge is accomplished ASAP afterwards. | Lead-acid chemistries prefer light cycling and full recharge between those cycles. Lead-acid batteries are traditional cycled to [[electrical:depth_of_discharge|50% depth of discharge]] because it offers a balance between duty life (years between failure) and bank size.(("dead lead")) Pulling the bank below 50% DoD in emergnecies will not automatically cause damage //assuming a full charge is accomplished ASAP//. |
| |
This article is about the intentional and chronic depletion of lead-acid banks below the 50% mark. | This article is about the intentional severe use of lead-acid banks by running them below the 50% mark, **followed by vigorous recharging** at maximal voltage.((the high end of the acceptable Absorption range. Maybe even EQ)). Perhaps [[electrical:12v:eternal_absorption|forgoing Float altogether]]. This might be desirable when: |
| |
| * reducing the weight impact of lead banks |
| * one wants to make use of old/damaged batteries whose capacity has declined |
| |
===== how low can we go? ===== | ===== how low can we go? ===== |
| |
| |
| * get power back into the battery ASAP after deep discharge; drive for [[electrical:12v:alternator|alternator charging]] or run a [[electrical:generator|generator]] to get bulk stage going. Solar alone //might// be sufficient but it might require meaningful [[electrical:solar:overpaneling|overpaneling]]. |
| * fully charge lead-chemistry batteries as often as possible. This may require [[electrical:12v:eternal_absorption|special measures to finishing Absorption]]. |
| |
Deep cycles generally extend the amount of time for a battery to complete Absorption. Extend the | |
| |
| |
| |