User Tools

Site Tools


electrical:severe_battery_use

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
electrical:severe_battery_use [2021/05/05 10:58]
frater_secessus [limiting the damage]
electrical:severe_battery_use [2021/08/15 19:56]
frater_secessus [Intentionally severe battery use]
Line 3: Line 3:
 Lead-acid chemistries prefer light cycling and full recharge between those cycles.  Lead-acid batteries are traditional cycled to [[electrical:depth_of_discharge|50% depth of discharge]] because it offers a balance between duty life (years between failure) and bank size.(("dead lead"))  Pulling the bank below 50% DoD in emergnecies will not automatically cause damage //assuming a full charge is accomplished ASAP//. Lead-acid chemistries prefer light cycling and full recharge between those cycles.  Lead-acid batteries are traditional cycled to [[electrical:depth_of_discharge|50% depth of discharge]] because it offers a balance between duty life (years between failure) and bank size.(("dead lead"))  Pulling the bank below 50% DoD in emergnecies will not automatically cause damage //assuming a full charge is accomplished ASAP//.
  
-This article is about the intentional severe use of lead-acid banks by running them below the 50% mark, **followed by vigorous recharging** at maximal voltage.  This might be desirable when:+This article is about the intentional severe use of lead-acid banks by running them below the 50% mark, **followed by vigorous recharging** at maximal voltage.((the high end of the acceptable Absorption range.  Maybe even EQ)).  Perhaps [[electrical:12v:eternal_absorption|forgoing Float altogether]].  This might be desirable when:
  
   * reducing the weight impact of lead banks   * reducing the weight impact of lead banks
Line 22: Line 22:
  
   * get power back into the battery ASAP after deep discharge;  drive for [[electrical:12v:alternator|alternator charging]] or run a [[electrical:generator|generator]] to get bulk stage going.  Solar alone //might// be sufficient but it might require meaningful [[electrical:solar:overpaneling|overpaneling]].     * get power back into the battery ASAP after deep discharge;  drive for [[electrical:12v:alternator|alternator charging]] or run a [[electrical:generator|generator]] to get bulk stage going.  Solar alone //might// be sufficient but it might require meaningful [[electrical:solar:overpaneling|overpaneling]].  
-  * fully charge lead-chemistry batteries as often as possible.  This may require [[electrical:12v:eternal_absorption|special measures to finishing Absporption]].+  * fully charge lead-chemistry batteries as often as possible.  This may require [[electrical:12v:eternal_absorption|special measures to finishing Absorption]].
  
  
  
electrical/severe_battery_use.txt ยท Last modified: 2024/03/30 21:42 by frater_secessus