Line 32: Line 32:
   * **12v/24v/48v** - this refers to the nominal voltage of the battery bank it will be charging.    * **12v/24v/48v** - this refers to the nominal voltage of the battery bank it will be charging. 
   * **Maximum input voltage** - the highest voltage the controller should //ever// see from the solar array.((it is common to leave ~20% margin))  NOTE: a 50v input max does //not// mean a PWM controller can make efficient use of mismatched panel/battery voltages; that requires MPPT.  See [[#how_to_choose|how to choose]] below.   * **Maximum input voltage** - the highest voltage the controller should //ever// see from the solar array.((it is common to leave ~20% margin))  NOTE: a 50v input max does //not// mean a PWM controller can make efficient use of mismatched panel/battery voltages; that requires MPPT.  See [[#how_to_choose|how to choose]] below.
 +  * **Minimum input voltage** - a PWM controller will requires panel voltage ≥ battery voltage to charge.  MPPT controllers will usually require a bit more voltage headroom to start/run the MPPT algorithm.((although less common, //boosting// MPPT do exist that can increase incoming voltage in order to charge a higher-voltage battery bank))
  
  