Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:solar:charge_controller [2022/05/03 11:09] frater_secessus [how to choose] removed footnote, inlined the comment |
electrical:solar:charge_controller [2022/08/03 19:58] frater_secessus [connection order] |
||
---|---|---|---|
Line 185: | Line 185: | ||
Note: in wind and hydro power applications the output can be sequenced so that LOAD is activated only when batteries are fully charged. | Note: in wind and hydro power applications the output can be sequenced so that LOAD is activated only when batteries are fully charged. | ||
+ | |||
+ | |||
+ | ===== connection order ===== | ||
+ | |||
+ | Solar charge controllers use the battery bank to provide a reference voltage for operation. | ||
+ | |||
+ | - disconnect solar panels | ||
+ | - disconnect battery | ||
+ | - wait a moment | ||
+ | - connect battery, wait for controller to power on | ||
+ | - connect solar panels | ||
+ | |||
+ | |||
+ | |||