 Regardless of type, controllers will have several specifications in common.  Regardless of type, controllers will have several specifications in common. 
  
-  * **rating (or "size")** - this is usually the maximum output the controller can produce (charging + loads).((for technical reasons with PWM this will also be the *input* current limit))+  * **rating (or "size")** - this is usually the maximum output in A (amps) the controller can produce (charging + loads).((for technical reasons with PWM this will also be the *input* current limit))
   * **12v/24v/48v** - this refers to the nominal voltage of the battery bank it will be charging.    * **12v/24v/48v** - this refers to the nominal voltage of the battery bank it will be charging. 
   * **Maximum input voltage** - the highest voltage the controller should //ever// see from the solar array.((it is common to leave ~20% margin))  NOTE: a 50v input max does //not// mean a PWM controller can make efficient use of mismatched panel/battery voltages; that requires MPPT.  See [[#how_to_choose|how to choose]] below.   * **Maximum input voltage** - the highest voltage the controller should //ever// see from the solar array.((it is common to leave ~20% margin))  NOTE: a 50v input max does //not// mean a PWM controller can make efficient use of mismatched panel/battery voltages; that requires MPPT.  See [[#how_to_choose|how to choose]] below.