Line 24: Line 24:
   * SNA (grid tied): Vpanel = desired output * 1.4142((https://www.researchgate.net/profile/Aalok_Bhatt/post/How_to_select_MPPT_Range_of_Solar_Inverter/attachment/59d624496cda7b8083a1f834/AS%3A377507284045824%401467016158673/download/SMA+Datasheet.pdf))   * SNA (grid tied): Vpanel = desired output * 1.4142((https://www.researchgate.net/profile/Aalok_Bhatt/post/How_to_select_MPPT_Range_of_Solar_Inverter/attachment/59d624496cda7b8083a1f834/AS%3A377507284045824%401467016158673/download/SMA+Datasheet.pdf))
   * EpEver:  Vpanel >= Vbatt +2v to start MPPT.((https://www.epsolarpv.com/upload/cert/file/1811/Tracer-AN(50-100A)-SMS-EL-V1.1.pdf))   * EpEver:  Vpanel >= Vbatt +2v to start MPPT.((https://www.epsolarpv.com/upload/cert/file/1811/Tracer-AN(50-100A)-SMS-EL-V1.1.pdf))
 +  * Midnite requires Vbatt+30%((https://www.midnitesolar.com/sizingTool/index.php))
   * generic rule of thumb:  Vpanel >= maximum Vbatt + 30%    * generic rule of thumb:  Vpanel >= maximum Vbatt + 30% 
   * generic rule of thumb:  Vpanel <= maximum Vbatt * 2.((https://www.homepower.com/input-voltage-controller-efficiency))((https://forum.solar-electric.com/discussion/351037/recomended-mppt-input-voltage-for-a-48-volt-system)).    * generic rule of thumb:  Vpanel <= maximum Vbatt * 2.((https://www.homepower.com/input-voltage-controller-efficiency))((https://forum.solar-electric.com/discussion/351037/recomended-mppt-input-voltage-for-a-48-volt-system)). 