electrical:solar:mppt_design [2021/07/19 23:09]
frater_secessus [input voltage]
electrical:solar:mppt_design [2023/01/22 15:35] (current)
frater_secessus [input voltage]
Line 1: Line 1:
 ====== MPPT integration ====== ====== MPPT integration ======
  
-There are benefits from using [[electrical:solar:panels#panel_voltage|higher voltage panels]] that can be realized when a system is designed for an MPPT controller.  An MPPT controller can also be the centerpiece of [[electrical:converter#diy_converters|a DIY converter]].+There are benefits from using [[electrical:solar:panels#panel_voltage|higher voltage panels]] that can be realized when a system is designed for an MPPT controller.  $/watt ratios can become quite favorable with large, used panels and [[electrical:solar:overpaneling|overpaneled]] controllers.  
 + 
 +The downside is that MPPT //requires// some amount of excess panel voltage over charging voltage to do its work (see below).  MPPT advantage may be minimal or nonexistant when nominal panel voltage matches nominal battery bank voltage (12v panels and 12v battery, for example).  Consider this worst-case scenario: 
 + 
 +  * low Vmp 12v panel, like a poly panel with Vmp of 17v 
 +  * 90F ambient temps,  which derates panel by 18% (Vmp is now 13.94) 
 +  * wiring losses of 2% (panel voltage entering controller is now 13.66v) 
 +  * a controller that requires Vbatt + 1v to maintain MPPT operation 
 + 
 +In this situation the controller **can't do MPPT charging above 12.66v**;  we have effectively wasted our money on that expensive MPPT.  So make sure there is sufficient (voltage) headroom for the MPPT to operate.  This can be done with higher-Vmp panels((like high-efficiency mono panels)), higher-voltage panels((20-24v)), or panels in series.  Example:  2x 12v panels in series is nominal 24v, a great fit for charging a 12v battery bank
  
  
Line 9: Line 18:
  
  
-MPPT manufacturers always specify a maximum voltage coming into the controller;  some also specify a minimum or optimium voltage  +MPPT manufacturers always specify a maximum voltage coming into the controller;  some also specify a minimum or optimium voltage for MPPT operation:   
  
   * Victron:  Vpanel >= Vbatt + 5v to start MPPT, Vbatt + 1v thereafter.((https://www.victronenergy.com/upload/documents/Manual-BlueSolar-charge-controller-MPPT-75-10-75-15--100-15-EN-NL-FR-DE-ES-SE-ul.pdf))   * Victron:  Vpanel >= Vbatt + 5v to start MPPT, Vbatt + 1v thereafter.((https://www.victronenergy.com/upload/documents/Manual-BlueSolar-charge-controller-MPPT-75-10-75-15--100-15-EN-NL-FR-DE-ES-SE-ul.pdf))
Line 15: Line 24:
   * SNA (grid tied): Vpanel = desired output * 1.4142((https://www.researchgate.net/profile/Aalok_Bhatt/post/How_to_select_MPPT_Range_of_Solar_Inverter/attachment/59d624496cda7b8083a1f834/AS%3A377507284045824%401467016158673/download/SMA+Datasheet.pdf))   * SNA (grid tied): Vpanel = desired output * 1.4142((https://www.researchgate.net/profile/Aalok_Bhatt/post/How_to_select_MPPT_Range_of_Solar_Inverter/attachment/59d624496cda7b8083a1f834/AS%3A377507284045824%401467016158673/download/SMA+Datasheet.pdf))
   * EpEver:  Vpanel >= Vbatt +2v to start MPPT.((https://www.epsolarpv.com/upload/cert/file/1811/Tracer-AN(50-100A)-SMS-EL-V1.1.pdf))   * EpEver:  Vpanel >= Vbatt +2v to start MPPT.((https://www.epsolarpv.com/upload/cert/file/1811/Tracer-AN(50-100A)-SMS-EL-V1.1.pdf))
 +  * Midnite requires Vbatt+30%((https://www.midnitesolar.com/sizingTool/index.php))
   * generic rule of thumb:  Vpanel >= maximum Vbatt + 30%    * generic rule of thumb:  Vpanel >= maximum Vbatt + 30% 
   * generic rule of thumb:  Vpanel <= maximum Vbatt * 2.((https://www.homepower.com/input-voltage-controller-efficiency))((https://forum.solar-electric.com/discussion/351037/recomended-mppt-input-voltage-for-a-48-volt-system)).    * generic rule of thumb:  Vpanel <= maximum Vbatt * 2.((https://www.homepower.com/input-voltage-controller-efficiency))((https://forum.solar-electric.com/discussion/351037/recomended-mppt-input-voltage-for-a-48-volt-system)). 
  
 +
 +===== other uses =====
 +
 +
 +An MPPT controller can also be the centerpiece of [[electrical:converter#diy_converters|a DIY converter]].