User Tools

Site Tools


electrical:solar:panel-bank_ratio

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
electrical:solar:panel-bank_ratio [2021/11/07 16:11]
frater_secessus [battery health] added Li charging info
electrical:solar:panel-bank_ratio [2022/01/03 12:50]
frater_secessus [1:1] blog link
Line 4: Line 4:
 ===== 1:1 ===== ===== 1:1 =====
 //1:1// == 200W solar + 200Ah battery bank. //1:1// == 200W solar + 200Ah battery bank.
-This generally considered the minimum, though it will likely work out fine in [[electrical:solar:output|sunny areas]] with light [[electrical:12v:loads|loads]].  It may not be enough in the winter when the sun is low and daylight short.+This generally considered the minimum, though it will likely work out fine in [[electrical:solar:output|sunny areas]] with light [[electrical:12v:loads|loads]].  It [[https://mouse.mousetrap.net/blog/2020/07/02/the-problems-with-11-solar-charging/|may not be enough]] in the winter when the sun is low and daylight short.
 [[electrical:solar:rationing|Power rationing]] may be necessary. [[electrical:solar:rationing|Power rationing]] may be necessary.
  
Line 12: Line 12:
  
   * add [[electrical:12v:alt_and_solar|another source of charging]]   * add [[electrical:12v:alt_and_solar|another source of charging]]
 +  * use a battery chemistry that charges more efficiently and doesn't mind [[electrical:12v:psoc|PSoC]] (like [[electrical:12v:deep_cycle_battery#lithium_chemistries|lithium]])
   * fully-charging lead becomes possible with attentive panel tilt, requiring only 5.5hrs on MPPT and 6.4hrs on PWM.   * fully-charging lead becomes possible with attentive panel tilt, requiring only 5.5hrs on MPPT and 6.4hrs on PWM.
   * fully-charging lead becomes possible with shallower cycling, like 75%.  This is the equivalent of the 2:1 systems below.    * fully-charging lead becomes possible with shallower cycling, like 75%.  This is the equivalent of the 2:1 systems below. 
electrical/solar/panel-bank_ratio.txt ยท Last modified: 2023/10/22 10:45 by frater_secessus