Line 4: Line 4:
 ===== 1:1 ===== ===== 1:1 =====
 //1:1// == 200W solar + 200Ah battery bank. //1:1// == 200W solar + 200Ah battery bank.
-This generally considered the minimum, though it will likely work out fine in [[electrical:solar:output|sunny areas]] with light [[electrical:12v:loads|loads]].  It may not be enough in the winter when the sun is low and daylight short. +This is generally considered the minimum, as it can work fine in [[electrical:solar:output|sunny areas]] with light [[electrical:12v:loads|loads]] and shallow [[electrical:depth_of_discharge|depths of discharge]].((10-20% DoD?))  It may not be enough with heavier use, or in the winter when the sun is low and daylight short.  [[electrical:solar:rationing|Power rationing]] may be necessary.
-[[electrical:solar:rationing|Power rationing]] may be necessary+
- +
-Working backwards, fully charging lead-chemistries by 1:1 solar means requires about 8.45hrs of Full Sun Equivalent on MPPT, and about 9.7hrs FSE with PWM. **There is nowhere in the United States that averages 8.45hrs of FSE year around**.  The highest is Honolulu with an average of 5.96hrs. The highest monthly average is Las Vegas in June (7.69hrs).+
  
 +[[https://mouse.mousetrap.net/blog/2020/07/02/the-problems-with-11-solar-charging/|Working backwards]], fully charging lead-chemistries from 50% [[electrical:depth_of_discharge|DoD]] by 1:1 solar requires  ~8.45hrs of [[electrical:solar:output#insolation_maps|Full Sun Equivalent]] on MPPT [[electrical:solar:charge_controller|controllers]], or ~9.7hrs FSE with PWM. [[https://mouse.mousetrap.net/blog/2020/07/02/the-problems-with-11-solar-charging/|There is nowhere in the continental United States]] that has enough insolation to get the job done with a 1:1 ratio.  
  
 +Workarounds:
  
 +  * add [[electrical:12v:alt_and_solar|another source of charging]]
 +  * use a battery chemistry that charges more efficiently and doesn't mind [[electrical:12v:psoc|PSoC]] (like [[electrical:12v:deep_cycle_battery#lithium_chemistries|lithium]])
 +  * fully-charging lead becomes possible with attentive panel tilt, requiring only 5.5hrs on MPPT and 6.4hrs on PWM.
 +  * fully-charging lead becomes possible with shallower cycling, like 75%.  This is the equivalent of the 2:1 systems below. 
  
 ===== 2:1 overpaneling ===== ===== 2:1 overpaneling =====
Line 25: Line 28:
 'Dwellers in the Pacific Northwest(("Northwet")) may need a 3:1 ratio to meet basic needs. 'Dwellers in the Pacific Northwest(("Northwet")) may need a 3:1 ratio to meet basic needs.
  
-Working backwards, successfully fully charging lead-chemisties by solar means only requires about 2.83hrs of Full Sun Equivalent on MPPT, and about 3.25hrs FSE with PWM.+Working backwards, successfully fully charging lead-chemistries by 3:1 solar requires about 2.83hrs of Full Sun Equivalent on MPPT, and about 3.25hrs FSE with PWM.
  
-On average this this opens up everything but Canada and Anchorage AK. +On //average// this this opens up everything but Canada and Anchorage AK. 
 ===== 1:2 underpaneling ===== ===== 1:2 underpaneling =====
 //1:2// == 100W solar + 200Ah of battery.  //1:2// == 100W solar + 200Ah of battery. 
Line 39: Line 42:
 Different battery types have different charging requirements: Different battery types have different charging requirements:
  
-  * lithium - no minimum, charge at any rate up to the max+  * lithium - no minimum, charge at any rate((see [[electrical:12v:drop-in LiFePO4#an_approach_to_greater_longevity|this article]] on gentler charging for longevity)) up to the max
   * flooded lead-acid:  minimum [[electrical:12v:battery_capacity|C]]/10 (10A per 100ah of capacity)   * flooded lead-acid:  minimum [[electrical:12v:battery_capacity|C]]/10 (10A per 100ah of capacity)
     * minimum ratio with MPPT = 1.25w:1ah     * minimum ratio with MPPT = 1.25w:1ah