Line 158: Line 158:
  
 ==== morning ==== ==== morning ====
-**Are your batteries at a reasonable [[electrical:depth_of_discharge|50% state of charge]]in the morning?**((≥50% or ~12.1v for lead batts, ≥20% for Lithium))  If so, continue to Afternoon.  +**Are your batteries at a reasonable [[electrical:depth_of_discharge|state of charge]] in the morning?**((≥50% or ~12.1v for lead batts, ≥20% for Lithium))  If so, continue to Afternoon.  
  
 If not, address this issue soon because discharging too deeply will [[electrical:batterycide|damage the batteries]].  Consider these changes: If not, address this issue soon because discharging too deeply will [[electrical:batterycide|damage the batteries]].  Consider these changes:
Line 170: Line 170:
  
 ==== afternoon ==== ==== afternoon ====
-**Are your batteries starting Absorption by noon-ish** and completing Absorption by late afternoon? If so, continue to the next step.  +**Are your batteries starting Absorption by noon-ish** and completing Absorption by late afternoon?((depending on charging voltage and current Lithium may require no absorption at all to reach 100% SoC)) If so, continue to the next step.  
  
 Note:  You can tell your batteries are in Absorption because the bank will be at Vabs, the controller's absorption setpoint. Note:  You can tell your batteries are in Absorption because the bank will be at Vabs, the controller's absorption setpoint.