This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:solar:status [2022/02/27 13:36] frater_secessus [morning] |
electrical:solar:status [2022/02/27 13:38] frater_secessus [evening] |
||
---|---|---|---|
Line 158: | Line 158: | ||
==== morning ==== | ==== morning ==== | ||
- | **Are your batteries at a reasonable [[electrical: | + | **Are your batteries at a reasonable [[electrical: |
If not, address this issue soon because discharging too deeply will [[electrical: | If not, address this issue soon because discharging too deeply will [[electrical: | ||
Line 170: | Line 170: | ||
==== afternoon ==== | ==== afternoon ==== | ||
- | **Are your batteries starting Absorption by noon-ish** and completing Absorption by late afternoon? If so, continue to the next step. | + | **Are your batteries starting Absorption by noon-ish** and completing Absorption by late afternoon?((depending on charging voltage and current Lithium may require no absorption at all to reach 100% SoC)) If so, continue to the next step. |
Note: You can tell your batteries are in Absorption because the bank will be at Vabs, the controller' | Note: You can tell your batteries are in Absorption because the bank will be at Vabs, the controller' | ||
Line 177: | Line 177: | ||
==== evening ==== | ==== evening ==== | ||
- | **Are you hitting sundown with //at least// 12.6-12.7v((depending on your particular battery)) in your lead acid bank? | + | **Are you hitting sundown with //at least// 12.6-12.7v((depending on your particular battery)) in your lead acid bank?**((~13.2v for LiFePO4)) |
If not, either we are not harvesting enough power or we are using too much. Stop running heavier loads when the controller can no longer hold Vfloat. | If not, either we are not harvesting enough power or we are using too much. Stop running heavier loads when the controller can no longer hold Vfloat. |