User Tools

Site Tools


hvac:roof_vent

This is an old revision of the document!


Roof vents

sizing

The industry standard for RV roof vents is 14“x14”.1) OEM vents are often substandard, lacking cowling around the fan that would move more CFM.

placement

There several and sometimes conflicting factors affecting vent placement.

  • for effective cross-ventilation throughout the length of the van one would put the fan at the opposite end of the fresh air intake. For example, if the front windows were to be cracked for inlet then the exhaust fan could be placed at the rear.
  • for direct breeze at night the vent might be placed in the sleeping area.2)
  • for protection from rainfall at night3), the fan might be placed away from the sleeping area
  • for cooking exhaust the vent would be placed over the cooking area.

rainproofing

OEM vents are very simple and will let rain in if left open. There are several ways to deal with this issue:

Be diligent about closing the vents manually. Easier said than done.

images-na.ssl-images-amazon.com_images_i_31z-qrf-8ll._ac_us160_.jpg Install a vent cover; this will allow for ventilation during bad weather. It also has a bonus function of decreasing sun and weather damage to the actual vent. Be sure your chosen vent is has enough room for complete movement of the vent's lid. Application notes:

images-na.ssl-images-amazon.com_images_i_51iws73dutl._ac_us160_.jpgSelect a vent with a rain-sensing function that will close the vent automatically, like the Fantastic Vent 807351. The manufacturer explains: “When dome (lid) is open and moisture contacts the sensor, the dome closes and turns fan blade motor off if it is running. When the rain sensor dries, dome reopens and fan blade motor runs if fan was running when dome closed.”6)

If the vent closes/opens on its own without rain the sensor may be dirty. It can be cleaned with a cloth and alcohol.7) A malfunctioning thermostat can also cause unexpected opening.8)

images-na.ssl-images-amazon.com_images_i_31sj6fh6mql._ac_us160_.jpgSelect a vent with an integral cover, like the MaxxFan 0007000K

features

More expensive fans have features that some will find worthwhile:

  • thermostat to control fan
  • more fan speeds
  • rain detection and auto-close
  • remote

roof vents in summer

Since hot air rises, you may get best results in summer by using the fan to blow air out of the camper. If you have a ventilation intake under your vehicle you may be able to pull in relatively cool air.

roof vents in winter

In winter you may want to run the vent on the lowest setting pulling air into the camper. This will preserve your warm air at the roof, contribute to circulation of air, and help control humidity.

power consumption

i.redd.it_ii18f5vmm9l01.jpgFans will use various levels of power at their different speed settings. For example, a 10-speed Maxxair consumes between 0.1A at lowest speed to almost 3A at full speed. See the pic to the right for one user's measurements.

The base 3-speed Fantastic model reportedly consumes 1A, 2A, and 3A respectively.9)