     * it will adjust to changing conditions, but it can be slow.  One might say "plodding".       * it will adjust to changing conditions, but it can be slow.  One might say "plodding".  
     * it can be slow to react after long periods of no load - see [[https://www.reddit.com/r/SolarDIY/comments/ttxs1b/switched_to_lifepo4_some_questions/i30s3ve/|this reddit post]] where I describe the phenomenon     * it can be slow to react after long periods of no load - see [[https://www.reddit.com/r/SolarDIY/comments/ttxs1b/switched_to_lifepo4_some_questions/i30s3ve/|this reddit post]] where I describe the phenomenon
-    * it can get confused in complex solar conditions, as with partly-cloudy skies and high winds, or in breezes that move partial shade around on the panels.  In these conditions Vpanel can fall to just above Vbatt, severely hobbling solar harvest.((effectively matching PWM output))+    * it can get confused in complex solar conditions, as with partly-cloudy skies and high winds, or in breezes that move partial shade around on the panels.  In these conditions Vpanel can crash to just above Vbatt, severely hobbling solar harvest.((effectively matching PWM output))
   * the large AN controllers (≥50A) have **undersized terminal screws** which can snap under overzealous tightening.  IMO EpEver should update the design with hefty BN-series terminal screws.    * the large AN controllers (≥50A) have **undersized terminal screws** which can snap under overzealous tightening.  IMO EpEver should update the design with hefty BN-series terminal screws. 
   * firmware does not appear to be field-upgradable without hacking   * firmware does not appear to be field-upgradable without hacking
Line 64: Line 64:
  
  
 +>> im having the same issue with epever charge controller. Early morning before the sun fully hits the panels 17 volts and .5 amps from a 60 volt array 300 watt array. I can unplug the panels and reconnect at it goes up to 57 or so volts then slowly drifts back to 17 again. Does the tracking just not work right or what is your opinion. I ran 2 100 watt 18.9 vmp panels on the epever. And 2 on a pwm. The mppt would go from 150 watts in full sun to 100 watt output every 20 minutes or so. And the pwm would steady put out 148 watts. In an all day comparison pwm won producing more watt hours.((https://forum.solar-electric.com/discussion/comment/397054/#Comment_397054))
  
 +>> I threw out my EPSolar Tracers for the same reason, equal paneling with correct voltages in a test of 3 EP Solar Tracers verses 3 Trace C-40 PWM The old trace units preformed much better. ... [the epever] would slowly sink in PV input volts until reset or maybe 20-30 minutes later would do a full sweep and come up to a decent input voltage. I bought a Classic.....problems gone((https://forum.solar-electric.com/discussion/comment/397055#Comment_397055))
  