[[lifestyle:words_of_wisdom|Words of Wisdom]]: "You have to build for winter, and figure out what to do with the extra electricity in summer." -- timselectric((https://diysolarforum.com/threads/less-than-perfect-off-grid-system.35869/post-450655)) | [[lifestyle:words_of_wisdom|Words of Wisdom]]: "You have to build for winter, and figure out what to do with the extra electricity in summer." -- timselectric((https://diysolarforum.com/threads/less-than-perfect-off-grid-system.35869/post-450655)) |
| |
====== solar sizing - the Big Picture ====== | ====== power system sizing - the Big Picture ====== |
| |
There are many [[electrical:solar:sizing#calculators|calculators where you can plug in the numbers]]. This page is a 35,000ft view of how choices affect what you will need. | There are many [[electrical:solar:sizing#calculators|calculators where you can plug in the numbers]]. This page is a 35,000ft view of how choices affect what you will need. |
| |
| |
==== controller sizing ==== | === controller sizing === |
| |
[[electrical:solar:charge_controller|Controllers]] are rated by the Amps they can pump out. A 20A controller can handle up to 20 Amps (about 250w incoming power, depending on battery voltage). | [[electrical:solar:charge_controller|Controllers]] are rated by the Amps they can pump out. A 20A controller can handle up to 20 Amps (about 250w incoming power, depending on battery voltage). |
| |
| |
| |
===== battery bank ===== | |
Having an **undersized bank** means //running out of power// at night. Sitting in the dark at night with no fan. | |
| |
Having an **oversized lead bank** for your charging ability results in [[electrical:batterycide|battery murder]] and replacement. Having an **oversized lithium bank** is $$$ and can strain the alternator if [[electrical:12v:b2b|a current-limiting isolator]] isn't used. | |
| |
IMO, with lead chemistries((flooded, agm, gel)) it is better to have an undersized bank you can charge //fully and consistently// rather than a bigger bank you cannot charge. | |
| |
You will **need somewhat more Ah capacity** | |
| |
* if you have undersized solar | |
* you have lead-chemistry battery bank | |
| |
You will need **somewhat less Ah capacity** | |
| |
* if you run loads in the daytime instead of at night | |
* if you have [[electrical:solar:overpaneling|oversized solar]] | |
* you have lithium-chemistry battery bank((can be ~0.62% the size of the lead bank, due to deeper [[electrical:depth_of_discharge|DoD]].)) | |
| |
| |