 +=== observing the regulation ===
 +
 +Some vehicle manufacturers have extended OBD2 pids that allow monitoring of the field signal that is regulating the alternator:
 +
 +  * Ford - Generator Field Control Output (%)((https://www.fordservicecontent.dealerconnection.com/pubs/content/~WVX2/~MUS~LEN/15/VX22007.HTM))
 +  * GM - Generator F-Terminal Signal ((https://www.autometer.com/obd2_gm))
  