This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
electrical:12v:b2b [2024/05/17 11:28] frater_secessus [Renogy] |
electrical:12v:b2b [2024/06/02 20:28] (current) frater_secessus [Renogy] |
||
---|---|---|---|
Line 32: | Line 32: | ||
See [[electrical: | See [[electrical: | ||
+ | |||
+ | ==== triggering / isolation ==== | ||
+ | |||
+ | The general idea is to feed power from the chassis (usually the starter battery) to the house battery **only when the alternator is making power**, and isolate the two from each other when it is not. The DC-DC will handle this in one of two ways: | ||
+ | |||
+ | * **voltage sensing** - watching chassis voltage like [[electrical: | ||
+ | * by receiving a **trigger signal** (AKA " | ||
+ | |||
+ | Product documentation will tell you how the unit is triggered.((sometimes both methods are used together)) | ||
===== sizing ===== | ===== sizing ===== | ||
Line 163: | Line 172: | ||
This version is for both **12v and 24v banks**. | This version is for both **12v and 24v banks**. | ||
- | The [[https:// | + | The [[https:// |
+ | |||
+ | >> Ensure that the open circuit voltage of the solar panel/solar panel array does not exceed 50V | ||
Update: | Update: | ||
Line 179: | Line 190: | ||
The D**1**S series appears to be a DCC charger with higher PV input limits: | The D**1**S series appears to be a DCC charger with higher PV input limits: | ||
- | >> For [the] 30A battery charger, ensure that the working voltage of the solar panel / solar panel | + | >> For [the] 30A battery charger, ensure that the working voltage of the solar panel / solar panel array does not exceed **30V**. For [the] 50A battery charger, ensure that the working voltage of the solar panel / solar panel array does not exceed **50V**. |
- | array does not exceed **30V**. For [the] 50A battery charger, ensure that the working voltage of the | + | |
- | solar panel / solar panel array does not exceed **50V**. | + | |
[[https:// | [[https:// | ||
Line 294: | Line 303: | ||
{{ https:// | {{ https:// | ||
- | SRNE makes [[https:// | + | SRNE makes [[https:// |
* output rating based on solar. | * output rating based on solar. |