This is an old revision of the document!
PWM controllers are inexpensive and durable. Their chief downside is their ability to generate power is limited when battery voltage is low (MPPT output is unaffected by battery voltage). This page is intended to help people get the most out of their PWM system. It assumes the 'dweller owns a configurable PWM controller.
Note: much of this information also applies to tweaking shunt controllers.
During charging with a PWM controller the solar panel will be running at the voltage of the battery bank.1) Unfortunately, this is almost never the voltage at which the panel makes its rated power (Vmp). The panel will make less and less power when battery voltage is low.
This affects charging in all three charging stages but it is devastating in Bulk. Let's do some math to see why.2)
Consider the spec sheet for a random 100w panel (right). 100W is made when the panel is run at 17.8v (Vmp). We will use Imp for our math, but the absolute numbers are not important, only the pattern. Current will usually be less under normal conditions, but can spike to Isc under some conditions.
17.8v x 5.6A = 100w ←- rating under laboratory conditions3)
17.8v x 5.6A = 94.70w ←- MPPT running at 95% efficiency
PWM harvest
14.8v x 5.6A = 82.88w ←- power at a high Absorption voltage, as with flooded lead acid
14.4v x 5.6A = 80.64w ←- power at a lower Absorption voltage
14.2v x 5.6A = 79.52w ←- power at a low Absorption voltage
13.8v x 5.6A = 77.28W ←- power at high Float, as with deeply cycled banks
13.2v x 5.6A = 73.92W ←- power at low Float, as with lightly cycled banks
12.7v x 5.6A = 70.61W ←- power at 100% state of charge (SoC)
12.4v x 5.6A = 69.44W ←- power at 75% state of charge; bulk charging
12.1v x 5.6A = 67.76W ←- power at 50% state of charge; bulk charging
10.0v x 5.6A = 56.00W ←- battery bank accidentally run flat
This last number shows how far off PWM output can fall when battery voltage (Vbatt) is at its lowest.4) It's also when the battery needs the most current to get out of that deep cycle trough.
Here are steps to take to maximize power from the PWM controller, in order from greatest effect to least effect.
Choose panels with a Vmp spec as close to your battery voltage as possible; this will mean the panels will be running closer to their rated output.
Assuming a charging voltage of 14.2v, let's consider two different panels. Remember that Vmp x Imp = Pmax (rated power).