This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
electrical:solar:tracer [2021/07/17 21:17] frater_secessus [Triron series] |
electrical:solar:tracer [2022/02/26 15:49] frater_secessus [quirks] |
||
---|---|---|---|
Line 21: | Line 21: | ||
- | ==== quirks ==== | + | ===== quirks |
- | Some [[electrical: | + | Some [[electrical: |
- | - "Low Voltage Reconnect Voltage" | + | |
- | - "Boost Reconnect" | + | - "Low Voltage Reconnect Voltage" |
+ | - "Boost Reconnect" | ||
- Then "Float Charge" | - Then "Float Charge" | ||
- Then "Boost Charge" | - Then "Boost Charge" | ||
- Then " | - Then " | ||
- | - Then "Over Voltage Reconnect" | + | - Then "Over Voltage Reconnect" |
- | - Then " | + | - Then " |
- | - Then "Over Voltage Disconnect" | + | - Then "Over Voltage Disconnect" |
+ | |||
+ | **PARA errors** mean the internal logic of the setpoints has been violated: | ||
+ | |||
+ | > The **following rules** must be observed when modifying the parameter' | ||
+ | |||
+ | > Over Voltage Disconnect Voltage (load) > Charging Limit Voltage ≥ Equalize Charging Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging Voltage. | ||
+ | |||
+ | > Over Voltage Disconnect Voltage (load) > Over Voltage Reconnect Voltage (load) | ||
+ | |||
+ | > Low Voltage Reconnect Voltage (load) > Low Voltage Disconnect Voltage (load) ≥ Discharging Limit Voltage. | ||
+ | |||
+ | > Under Voltage Warning Reconnect Voltage (load)((low voltage warning turns off here)) > Under Voltage Warning Voltage (load) ≥ Discharging Limit Voltage (load)((no effect other than warning in standalone systems)) | ||
+ | |||
+ | > Boost Reconnect Charging voltage > Low Voltage Reconnect Voltage. | ||
+ | |||
+ | |||
+ | |||
+ | |||
{{http:// | {{http:// | ||
Tracer (and the Renogy rebrands) refer to the **Absorption stage as " | Tracer (and the Renogy rebrands) refer to the **Absorption stage as " | ||
+ | |||
+ | The LOAD icon (light bulb ON/OFF) indicates whether the LOAD terminals are powered, not whether or not anything is connected to them or consuming power. | ||
+ | |||
+ | |||
+ | === battery SOC icon === | ||
+ | |||
The **battery icon** found on many Tracer controllers is unnecessary and misleading. | The **battery icon** found on many Tracer controllers is unnecessary and misleading. | ||
| | **Charging**| | | | **Charging**| | ||
Line 42: | Line 68: | ||
| **0 bar / 0%: **| not charging| | | **0 bar / 0%: **| not charging| | ||
- | The LOAD icon (light bulb ON/OFF) indicates whether the LOAD terminals are powered, | + | ===== lithium compatibility ===== |
+ | |||
+ | EpEver says the Tracer series is not fully lithium compatible since they cannot " | ||
+ | |||
+ | There is anecdotal evidence that the PC software can configure the controller | ||
+ | |||
+ | * [[https:// | ||
+ | * [[https:// | ||
+ | |||
+ | ===== models ===== | ||
==== A series ==== | ==== A series ==== | ||
{{https:// | {{https:// | ||
Line 101: | Line 137: | ||
* negative ground | * negative ground | ||
* modular construction | * modular construction | ||
- | * battery voltage sense | + | * low temperature charging cutoff((https:// |
- | * relay interface rather than traditional LOAD output | + | |
- | + | ||
The Triron is also sold as the Renogy Rover, which can be programmed using the [[https:// | The Triron is also sold as the Renogy Rover, which can be programmed using the [[https:// | ||
+ | |||
+ | [[https:// | ||
Line 135: | Line 170: | ||
Note that these apps talk directly to the modules over BT/ | Note that these apps talk directly to the modules over BT/ | ||
+ | |||
+ | See [[https:// | ||
+ | |||
---- | ---- |