 +=== True Amalgamated Lithium VSR ===
  
 +True [[https://www.trueam.com/product/true-lithium-large-dual-battery-kit/|makes a VSR]] with 13.5v ON and 13.2v OFF setpoints. 
  
  
Line 578: Line 580:
   * VSR triggered by voltage can can be disabled by a switch on the thin ground wire on the VSR itself.((the VSR requires a ground to make a complete circuit to run internal electronics.  Breaking this circuit turns off the  VSR))     * VSR triggered by voltage can can be disabled by a switch on the thin ground wire on the VSR itself.((the VSR requires a ground to make a complete circuit to run internal electronics.  Breaking this circuit turns off the  VSR))  
   * some DC-DC can be //derated//((output intentionally reduced)) by providing a 12v signal to the CURRENT LIMIT terminal ([[electrical:12v:b2b#renogy1|Renogy DC1212 series]], [[electrical:12v:b2b#leaptrend|Leaptrend]]) or through a setting in an app (Renogy DCC50S).   * some DC-DC can be //derated//((output intentionally reduced)) by providing a 12v signal to the CURRENT LIMIT terminal ([[electrical:12v:b2b#renogy1|Renogy DC1212 series]], [[electrical:12v:b2b#leaptrend|Leaptrend]]) or through a setting in an app (Renogy DCC50S).
-  * some DC-DC can be //disabled// by providing a 12v signal to a remote ON/OFF terminal ([[electrical:12v:b2b#victron|Victron Orion-TR]]), Kisae.  +  * some DC-DC can be //disabled// by providing a 12v signal to a remote ON/OFF terminal ([[electrical:12v:b2b#victron|Victron Orion-TR]]), [[electrical:12v:b2b#disabling_the_kisae|Kisae]].  
   * on units that have a dedicated NEG ("ground", negative return) to the starter battery there may be no easy disable method.  The brute force method would be to insert a relay between the starter battery POS and the unit's POS input, and control the relay with a switch.    * on units that have a dedicated NEG ("ground", negative return) to the starter battery there may be no easy disable method.  The brute force method would be to insert a relay between the starter battery POS and the unit's POS input, and control the relay with a switch. 
   * bluetooth-enabled DC-DC can often be disabled or derated from the app   * bluetooth-enabled DC-DC can often be disabled or derated from the app