User Tools

Site Tools


electrical:solar:output

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
electrical:solar:output [2025/04/05 18:26]
frater_secessus [panel temperature]
electrical:solar:output [2025/06/18 22:30] (current)
frater_secessus [panel temperature]
Line 51: Line 51:
 ===== panel temperature ===== ===== panel temperature =====
  
-Solar panel voltage((and therefore output on MPPT controllers)) varies as cell temperature goes up (in the sun) or down (in very cold ambients).+Cell temperature affects the voltage part of the panel's I/V curve; warmer temps drive voltages down and very cold temperatures drive it up This is why Voc+20% or similar rules of thumb are used when assessing how much voltage "headroom" the solar charge controller has -- a cold snap could, for example, put a 48Voc rated array over a 50v controller input limit.   
 + 
 +For this reason the array's real-world Vmp is rarely the Vmp given on the lab rating.  It doesn't matter much to PWM but you will observe your MPPT finding a Vmp that does not match rated Vmp.  And since with MPPT ''Vmp * Imp = Mpp'' lower Vmp means lower harvest.  Hence the panel mounting airgap;  it allows cooling airflow underneath.  
 + 
 +==== high cell temperatures ==== 
  
-Usually the problem is increased cell temperature which drives down panel output.  This is the main reason panels are mounted with an airgap;  it allows cooling airflow underneath.  
  
 The data below, derived from [[http://digivation.com.au/solar/tempderate.php|this calculator]], show power from a 100W mono/poly panel dropping off as ambient temps rise:  The data below, derived from [[http://digivation.com.au/solar/tempderate.php|this calculator]], show power from a 100W mono/poly panel dropping off as ambient temps rise: 
Line 75: Line 79:
 Note: that [[hvac:insulation#heat_from_solar_panels|radiated heat from the underside of panels can raise temperatures inside the camper]]. Note: that [[hvac:insulation#heat_from_solar_panels|radiated heat from the underside of panels can raise temperatures inside the camper]].
  
-==== low ambient temperatures ====+==== low cell temperatures ====
  
  
-Sub-freezing ambients temperatures can push Voc/Vmp above their rated values.  If you will use solar in sub-freezing conditions leave plenty of Voc headroom in your solar charge controller spec. +20% margin is traditional.+Sub-freezing temperatures can push Voc/Vmp above their rated values.  If you will use solar in sub-freezing conditions leave plenty of Voc headroom in your solar charge controller spec. +20% margin is traditional.
  
  
electrical/solar/output.1743891984.txt.gz · Last modified: 2025/04/05 18:26 by frater_secessus