- | ==== where does it start? ==== | + | ==== narrowing it down ==== |
+ | |||
+ | We've come this far in the process and **this is our first attempt at doing what most people think of as troubleshooting** (testing with [[:# | ||
+ | |||
+ | === measuring voltage === | ||
+ | |||
+ | Measuring voltage with a 'meter is fundamental to troubleshooting in a van. Let's assume a lava lamp plugged into your 120vac circuit no longer works. | ||
+ | |||
+ | There are many points to test | ||
+ | |||
+ | - the 12v battery bank voltage at the terminals | ||
+ | - the 12v input terminals on the inverter | ||
+ | - the 120vac output terminals on the inverter | ||
+ | - 120vac outlet | ||
+ | |||
+ | In practice we usually don't need to test them all. We can make some fair assumptions on our preliminary investigation: | ||
+ | |||
+ | * if voltage at the battery is low (lead) or ~zero (lithium) the battery needs to be charged. If voltage is normal the problem probably lies elsewhere. | ||
+ | * if other things are running off the inverter right now then the problem is unlikely to be the inverter itself. | ||
+ | * if nothing is running off the inverter and there are not lights on it then a fuse may have popped. 0v at the inverter inputs will help confirm this. | ||
+ | * if the lava lamp doesn' | ||
+ | |||
+ | If things still don't make sense we might have to explicitly test those assumptions. | ||
+ | |||
+ | * if the battery terminal voltage sags under load the battery is undersized and/or unhealthy | ||
+ | * if battery voltage is ok but low at the inverter terminals then the [[electrical: | ||
+ | |||
+ | |||
+ | On wiring runs that do not have observable loads on them we might have to take a voltage reading at each one. If there are many connections you might start at the midpoint to rule out 50% of the possibilities, | ||
+ | |||
+ | Note: on circuits presently carrying power voltage testing is also indirectly continuity testing (see below). | ||
+ | |||
+ | |||
+ | === measuring current === | ||
+ | |||
+ | Sometimes voltage doesn' | ||
+ | |||
+ | Current measurements are also important for understanding how your system is functioning: | ||
+ | |||
+ | If you have [[electrical: | ||
+ | |||
+ | |||
+ | === measuring continuity === | ||
+ | |||
+ | Meters can measure continuity. | ||
+ | |||
+ | |||
+ | === measuring resistance === | ||
+ | |||
+ | Meters can also measure resistance but that is beyond the scope of this simple guide. | ||
+ | |||
+ | |||
+ | === testing components === | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||