 +Charging bottlenecks occur when the battery bank could happily [[opinion:frater_secessus:charging_faster|charge faster]] and more often but we aren't doing so.  
 +
 +A major cause of underperformance is **reliance on a single form of charging**.   The sun is not always out (solar), you are not always driving (charging from alternator), and access to the power grid is not always available (shore power). 
 +
 +
 +  * solar
 +    * maybe we have no solar at all
 +    * maybe we have unused roofspace to devote to more panel
 +    * maybe the panel we have is [[opinion:frater_secessus:beginner_mistakes#mounting_or_deploying_panels_where_they_will_be_shaded|shaded by other things on the roof]]
 +    * maybe we went with portable panels but [[https://rvwiki.mousetrap.net/doku.php?id=opinion:frater_secessus:beginner_mistakes#believing_they_will_set_out_portable_panels|don't deploy them consistently]] for whatever reason.  Some mounted panel could make a big difference.
 +    * maybe we went with mounted panels but park the rig in the shade.  Portables on extensions set out in the sun could make a big difference. 
 +  * alternator
 +    * maybe we are not charging from the alternator at all 
 +    * maybe we are forgetting to enable charging from the alt after [[electrical:12v:alternator#disabling_alternator_charging|disabling]] it
 +    * maybe the alternator has [[electrical:12v:alternator_details#current|excess capacity]] to devote to house bank charging
 +  * shore power
 +    * maybe we are not [[electrical:converter|charging from shore power]] at all when we have access to it
  
  
 === bank capacity bottlenecks === === bank capacity bottlenecks ===
 +
 +If you can charge the bank consistently but run out of power overnight or in periods of decreased harvest you may just need more bank capacity.  Also see [[electrical:autonomy|Days of Autonomy]].
 +
  
 === throughput bottlenecks === === throughput bottlenecks ===
  
 +These are related to the systems above, but are less obvious.
  
 +  * panels and PWM solar charge controllers poorly matched, resulting in [[electrical:solar:pwm_tweaking#pwm_s_achilles_heel|underperformance]]
 +  * insufficient panel wattage
 +  * panel wattage grossly oversized for the MPPT controller (>30% [[electrical:solar:overpaneling#vs_charge_controller|overpaneled]];  this is relatively rare)
 +  * DC-DC [[electrical:12v:b2b#sizing|undersized]] relative to the alternator and bank
 +  * wiring undersized for alternator charging with a combiner (relay/solenoid/"isolator", etc.  Since they don't alter voltage this kind of setup is sensitive to resistance between the chassis electrical and battery bank.
  
  