sizing a house battery bank
assumptions
factors
battery bank chemistry
usable capacity
lead-chemistry batteries (FLA, AGM, GEL) are typically
nominal 12v and discharged to 50%
Depth of Discharge. A 100Ah lead battery holds ~1,200Wh (100Ah x 12v), and one discharged to 50% holds 600Wh (1,200Wh x 0.5). It would take
166Ah of lead battery to give us 1,000Wh usable. (1,000Wh / 600Wh = 1.66 100Ah batteries)
lithium batteries are typically nominal 12.8v and discharged to 80% DoD. A 100Ah LFP battery holds 1,280Wh, of which 1,024Wh are usable (1,280Wh x 0.8). It would take 98Ah of LFP to give us 1,000Wh usable. (1,000Wh / 1,024Wh = ~0.98 100Ah batteries)
throughput
'Dwellers contemplating large currents relative to capacity (“C rates”) might have to oversize the bank to get sufficient throughput, and/or choose a chemistry with lower resistance. FLA are famously stingy with current, AGM good, and Lithium excellent.
load timing
The simplest model assumes the bank will be charged then all the loads will be run from the bank.
In real life sometimes loads are running while the system is making power.
running a 400w when solar is producing 200w means a net load of 200w.
running a 100w while alternator charging is producing may mean a net load of 0w (a freebie, in terms of battery capacity)
You may want to add a section to your DPR spreadsheet to account for load use while solar is present, etc. In extreme cases only a very small bank may be required if most loads are effectively run off the panel.
charging
charging stability and predictability
Charging can be very predictable or highly unpredictable. More predictable charging allows smaller battery banks, and less predictable charging may require bigger banks unaffected by PSoC to cover the variability.
shore power (plugged in somewhere) is extremely predictable. It will make 15.20A, 30A, whatever, as long as you are plugged in.
same for charging with
generator; as long as it's running you have predictable charging
alternator charging with DC-DC is relatively predictable; it will charge at the DC-DC's rated output until the bank hit's absorption
alternator charging with combiner is less predictable; it will tend to start off with higher current at lower SoC and taper off as the bank reaches the alternator voltage
solar charging is highly unpredictable, being greatly affected by weather and
other factors. Rigs with solar-only charging may have to plan for days of minimal harvest, or have the flexibility to reduce consumption when solar harvest is compromised.
minimum current requirements
Lead chemistries typically have minimum charging current requirements to stay healthy
If we cannot meet minimums the bank should be downsized (or charging increased).
Note: Lithium has no minimum charging current
maximum charging limits
Battery chemistries typically have maximum charging currents that can stress charging systems (particularly alternators via combiners):
FLA 0.20C (20A for every 100Ah of capacity)
AGM 0.33C (33A for every 100Ah of capacity)
LFP 1.0C (100A for every 100Ah of capacity)
If the alternator can only safely provide 50A of charging to the house bank this would limit us to a 166Ah AGM bank (166Ah x 0.33 = 50A). If the alternator has excess capacity then a larger bank can accept more current. This doesn't mean the bank would get full any faster1) but you will gather more Ah/Wh on any given run.