Words of Wisdom: “The response of a series parallel array to shade will be complicated.” – sensij1)

Partial shading

Partial shading can have surprisingly dramatic effects on panel output. Perhaps counterintuivitely, partial shading can have more devastating effects on output than full shading like heavy overcast or evenly shaded forest canopies.

panel configuration for partial shade

The way to avoid the problems associated with partial shade is to avoid partial shade. :-) Failing that, there are steps one can take to minimize the losses:

  • avoiding shade is best
  • a dedicated controller for each panel is the next best thing
  • amorphous/thin-film panels are less affected by shade
  • With PWM controllers, parallel panel configurations typically yield more power in partial shade than serial.
  • With MPPT controllers and low-ish voltage serial panel configurations (where the total Vmp is ⇐2x battery bank voltage) parallel will probably still yield more.

exception: high voltage strings + mppt

There is another approach, which is to bring the shaded cells/strings back online by bringing the rest of the panel down to their level. It sounds counterproductive, but with MPPT controllers and in some higher-voltage series configurations (say Vmp is >=3x bank voltage) it works.

This occurs because the MPPT has a broader range of voltages to sweep and can find other power peaks (panel voltages) that are low enough to bring the shaded cells back online but still high enough to charge the battery bank. It's not reality, but we can think of it as MPPT evenly “shading” the entire panel voltage-wise in order to get max juice from it in partial shade conditions.2)

why it works this way

[draft section]

This section will assume an array of 2x generic 100w 18Vmp panels

  • the panel is made up of 36 0.5Vmp cells in series for 18v; 36 x 0.5v = 18v.
  • since rated wattage is 100w, the cells must be 5.55Isc (amps at max power); 100w / 18v = 5.55A.

how the work normally

Under lab conditions the cells will each make 5.55A at 0.5v, delivering the rated 100w at 18v. In the real world the Vmp will likely be lower due to cell temperature derating and current will likely be much lower due to imperfect sun. But to keep things simple and numbers even we will assume lab conditions.

partial shade is bad for panels

* power moves in the direction of higher voltage to lower voltage. * when shaded sufficiently any given cell's voltage will drop off sharply3) * so power from neighboring cells moves into the cell instead of out of it * the cell converts this power into heat which can damage or destroy the cell, or catch the panel on fire

When the entire panel is lit or shaded evenly power is reduced but no individual cell is running at a lower voltage than its neighbor. So overcast days or dense tree canopies are not a problem.

so panel designers try to limit damage

We can't stop the cell voltage from collapsing in shade so we need a way to remove it, electrically, from the circuit.

which has observable effects on output

so users try different panel configurations

Before we begin: solar panels are “current sources”; their voltage pops up into the normal range in any kind of meaningful light(>= 20% insolation) but current will suffer. Partial shading in this context means:

  • light is falling on the panel
  • but not evenly on the panel – it is different on some cells

To prevent power from rushing into the shaded string and overheating them, panels have bypass diodes between the strings. Basically the shaded strings get cut off, electrically speaking, to protect them. In a perfect world each cell would be protect by a lossless, costless diode but that's not possible yet. :-)

further reading