Line 540: Line 540:
  
  
-DC-DC chargers in 20A, 40A, and 60A output.  Switched on by ignition circuit on the D+ port, low output mode (12.5% of rated current) triggered by 12v on a dedicated terminal. ((https://www.renogy.com/content/RNG-DCC1212-20-BC/DCC1212-204060-Manual.pdf)) DIP switches for battery type, Vabs and Vfloat. [[https://www.renogy.com/content/RNG-DCC1212-20-BC/DCC1212-204060-Manual.pdf|manual]] (pdf) [[https://diysolarforum.com/threads/renogy-dcc1212-dc-dc-charger-teardown.10141/|teardown]]  Note:  some versions of the manual [[https://www.reddit.com/r/vandwellers/comments/okfkuk/my_batteries_inverter_and_dcdc_charger_came_in_i/h5899bw/|may have a typo]].+DC-DC chargers in 20A, 40A, and 60A output.  Switched on by ignition circuit on the D+ port, low output mode (50% of rated current) triggered by 12v on a dedicated terminal. ((https://www.renogy.com/content/RNG-DCC1212-20-BC/DCC1212-204060-Manual.pdf)) DIP switches for battery type, Vabs and Vfloat. [[https://www.renogy.com/content/RNG-DCC1212-20-BC/DCC1212-204060-Manual.pdf|manual]] (pdf) [[https://diysolarforum.com/threads/renogy-dcc1212-dc-dc-charger-teardown.10141/|teardown]]  Note:  some versions of the manual [[https://www.reddit.com/r/vandwellers/comments/okfkuk/my_batteries_inverter_and_dcdc_charger_came_in_i/h5899bw/|may have a typo]].
  
 These chargers appear to have a 3 hour absorption duration.  This is usually insufficient for lead chemistries, but still longer than the 2 hour duration of the DCC series above.  From the manual: These chargers appear to have a 3 hour absorption duration.  This is usually insufficient for lead chemistries, but still longer than the 2 hour duration of the DCC series above.  From the manual:
electrical/12v/b2b.txt · Last modified: 2024/05/17 11:40 by frater_secessus