+ | NOTE: there are two distinct versions of the RBC line. Both appear to have PV input limits higher than 25v found in the older DCC line. Major differences appear to be: | ||
+ | |||
+ | * DS - built-in Bluetooth, support for both 12v/24v banks. | ||
+ | * D1S - no built-in Bluetooth, 12v banks only. Uses traditional DCC case. | ||
+ | |||
+ | |||
+ | == RBC2125DS == | ||
+ | |||
+ | |||
+ | {{ https:// | ||
Note: some manual versions brand this unit as part of the " | Note: some manual versions brand this unit as part of the " | ||
- | The [[https:// | + | This version is for both **12v and 24v banks**. |
+ | |||
+ | The [[https:// | ||
- | The existing [[https:// | + | >> Ensure that the open circuit voltage of the solar panel/solar panel array does not exceed 50V |
+ | Update: | ||
== solar+alternator behavior == | == solar+alternator behavior == | ||
Line 163: | Line 177: | ||
+ | == RBC30D1S and RBC50D1S == | ||
+ | The D**1**S series appears to be a DCC charger with higher PV input limits: | ||
+ | |||
+ | >> For [the] 30A battery charger, ensure that the working voltage of the solar panel / solar panel array does not exceed **30V**. For [the] 50A battery charger, ensure that the working voltage of the | ||
+ | solar panel / solar panel array does not exceed **50V**. | ||
+ | |||
+ | [[https:// | ||
Line 213: | Line 234: | ||
This unit also seems to be sold under the Ring and Merlin brands. | This unit also seems to be sold under the Ring and Merlin brands. | ||
+ | |||
+ | |||
+ | ==== LiTime ==== | ||
+ | |||
+ | {{ https:// | ||
+ | LiTime makes [[https:// | ||
+ | |||
+ | * Pv input 13.0v - 26v, max 600w | ||
+ | * Alternator Input Voltage 11.3-24VDC, max 600w | ||
+ | * Smart Alternator Input Voltage 12-24VDC , max 600w | ||
+ | |||
+ | |||
+ | === solar+alternator behavior === | ||
+ | |||
+ | According to the Amazon listing: | ||
+ | |||
+ | > The DC-DC charger will choose the DC input automatically rather than charging the service battery with both the solar and DC inputs | ||
+ | |||
+ | |||
+ | === starter battery maintenance behavior === | ||
+ | |||
+ | > When the starting battery voltage is between 3-12V and the living battery voltage is greater than 12.5V, press and hold " | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | ==== Redodo ==== | ||
+ | |||
+ | {{ https:// | ||
+ | Redodo makes [[https:// | ||
+ | |||
+ | * Pv input 13.0v - 26v, max 600w | ||
+ | * Alternator Input Voltage 11.3-24VDC, | ||
+ | * Smart Alternator Input Voltage 12-24VDC , max 600w | ||
+ | |||
+ | No manual located as of this writing. | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | === solar+alternator behavior === | ||
+ | |||
+ | unknown | ||
+ | |||
+ | === starter battery maintenance behavior === | ||
+ | |||
+ | Amazon listing claims " | ||
+ | |||
+ | > When the starter battery voltage is between 3 to 12V and the service battery voltage is >12.5V, press and hold the “Reverse Charging” for 3 seconds to initiate reverse charging. It’s recommended to exit reverse charging when the starter battery voltage >13V and charging current <10A, or when the service battery voltage < | ||
+ | |||
+ | |||
+ | |||
+ | |||