Words of Wisdom:
Over many years of capacity testing hundreds and hundreds of batteries, flooded, GEL and AGM I have yet to see a lead acid battery that could delivers its full storage potential at anything less than 0.75%
1) in tail current at absorption voltage. MaineSail
2)
Battery murder
Battery murder (or Batterycide) is the murder of batteries by abuse, misuse, inappropriate charging, etc. The term is commonly used by SternWake: “my goal here is to prevent batterycide.”3)
It is so common for new RVers to wreck their first set of house batteries that some recommend using cheap wally world batteries as sacrificial lambs to the learning process.4) As the RVers learns more and gets charging set up correctly they would invest in better quality batteries and have them last several years.
murdering flooded lead-acid
Flooded lead-acid (FLA) batteries are the most resillient to mistreatment but they too can be killed.
leaving them at
partial state of charge, resulting in
irreversible sulfation
5) Fully charging each day is optimal. Fully charging
almost every day is acceptable.
-
not holding Vabs for
sufficient duration so that absorption current drops to manufacturer-recommended levels.
Generator- or
DC-DC charging can cause this unless the charger runs the necessary number of hours it takes to complete Absorption.
discharging too deeply. Discharge with lead-chemistries is typically limited to 50%
depth of discharge as a compromise between cycle life and bank size.
allowing the cells to get low on distilled water. Check them 1x/month or so until you learn their personality.
exposing them to heat, as in an engine bay
murdering AGM
AGM have benefits but are easier to murder.
the lead-acid list above
8)
overvoltage
Low current charging. Cheap AGM require
C/5 current minimum in Bulk, and expensive ones require C/3.
murdering lithium
overvoltage.
13.8v is a safe upper limit without BMS and will charge the bank completely. Some experienced folk use slightly higher voltages for faster charging but it must be terminated quickly as the bank approaches 100% state of charge. Exception: Lithium banks with BMS typically overcharge intentionally to balance cells. The overcharge is consumed by resistors and does not actually go into the cell.
long periods of 100% state of charge; cease all charging at 100% and only charge that high if you know some loads will be applied immediately.
IF you're storing the van or know you're not going to be using the batteries for more than a couple days, it's strongly recommended to leave lithium batteries at 50-80% SOC. Lithium chemistries do not care about partial state of charge, and actually prefer it..
exposure to high heat
attempting to charge at below freezing
poor quality BMS
high [dis]charge rates without BMS